C-reactive Protein (CrP) Diagnostic Rapid Test Cassette , Accuate
Cardiac Marker Rapid Test Kits
A rapid test for the diagnosis of inflammatory condition by
detecting C-reactive protein qualitatively in whole blood, serum or plasma CE
certified
Applications:
The CRP Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid
chromatographic immunoassay for the qualitative detection of human
CRP in whole blood, serum or plasma as an aid in the diagnosis of
inflammatory condition. The cut-off of the test is 10 μg/ml.
Description:
C-reactive Protein (CrP) in patient’s sera has been found in
association with acute infections, necrotic conditions and a
variety of inflammatory disorders. There is a strong correlation
between serum levels of CrP and the onset of the inflammatory
process. Monitoring the levels of CrP in patient’s sera indicates
the effectiveness of treatment and the assessment of patient
recovery. It is used in particular to differentiate bacterial
infections from virus infections.
How to use?
Bring tests, specimens, buffer, and/or controls to room temperature
(15-30°C) before use.
1. Remove the Test Cassette from its sealed pouch, and place it on
a clean, level surface. For best results, the assay should be
performed within one hour.
2. Open the tube with the diluted sample .Transfer 3 drops of
(approx. 120ul) mixed specimens to sample well. Start the timer.
3. Wait for the colored lines to appear. The result should be read
at 5 minutes. Do not interpret the results at 10 minutes.
For CCR-401 :
The CRP Rapid Test Dipstick (Whole Blood/Serum/Plasma) is a rapid
chromatographic immunoassay for the qualitative detection of human CRP in whole
blood, serum or plasma as an aid in the diagnosis of inflammatory condition. The cutoff of
the test is 10 μg/ml.
SUMMARY
C-reactive Protein (CRP) in patient’s sera has been found in
association with acute infections, necrotic conditions and a variety of inflammatory
disorders.1 There is a strong correlation between serum levels of CRP and the onset of the
inflammatory process.Monitoring the levels of CRP in patient’s sera indicates the
effectiveness of treatment and the assessment of patient recovery.3 It is used in particular to
differentiate bacterial infections from virus infections.
PRINCIPLE
The CRP Rapid Test Dipstick (Whole Blood/Serum/Plasma) detects
C-reactive Protein through visual interpretation of color development on the internal
dipstick. The sample now moves through the test dipstick from bottom to top. If the test
sample contains CRP, it attaches to the CRP antibody which is conjugated with a red gold
colloidal for color marking. The more CRP is contained in the sample, the more red
lines become visible.
A red line should always appear in the control (C) line area. It
serves as a procedural control, confirming that sufficient specimen volume was used and
indicates an adequate membrane wicking and proper procedural technique.
DIRECTIONS FOR USE
Bring tests, specimens, buffer, and/or controls to room temperature
(15-30°C) before use.
1. Remove the Test Dipstick from its sealed pouch, and place it on
a clean, level surface.
For best results, the assay should be performed within one hour.
2. Open the tube with the diluted sample and put the test dipstick
with the arrow pointing end into the liquid. Make sure to dip the test not beyond the line
for the maximum immersion depth (Max line). Avoid in any case a direct wetting of
the result area by spilling or dipping the test beyond MAX line.
3. Leave the test for minimum 10 seconds in the diluted sample
until the slightly pink-colored liquid front becomes visible in the result area.
4. Take out the test dipstick and place it on a plain and
non-absorbent surface. Alternatively, the test dipstick can remain in the tube. Start the
timer as the test starts to run.
5. As the test begins to run you will observe a colored liquid
migrate along the membrane of the reaction area. Interpret results at 5 minutes. Please stick
exactly to this time line to ensure correct semi-quantitative results.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
POSITIVE:* Two lines appear. One colored line should be in the
control line region (C) and another apparent colored line should be in the test line region
(T).
*NOTE: The intensity of the color in the test line region (T) will
vary depending on the concentration of CRP antigen present in the specimen. Therefore,
any shade of color in the test line region (T) should be considered positive.
NEGATIVE: One colored line appears in the control line region (C).
No line appears in the test line region (T).
INVALID: Control line fails to appear. Insufficient specimen volume
or incorrect procedural techniques are the most likely reasons for control line
failure. Review the procedure and repeat the test with a new test. If the problem
persists, discontinue using the test kit immediately and contact your local distributor.