Kettle Insert-withdraw Endurance Test Device
Product information:
The kettle insert-withdraw endurance test device is designed and
manufactured according to the standard IEC60335 -2- 15 which is
used to test the cordless kettle plug life.
Test principle and product feature:
Test principle:The device is driven by the motor and crank
connecting link. And the kettle is pulled out for 10000 times at
the rate of 10 times per minute. Then under the circumstance
without power supply, the test is done for another 10000 times.
When doing the load test, the two conductive pins are shorted with
the external load of the rated voltage and 11 times of rated
current.
Product feature:The equipment inside is equipped with load, so it
is unnecessary to connect with external one. Insert the sample into
the Load interface, thus the load test can be achieved. There are
two test modes of this device: automatic test and manual test. When
it is switched into the automatic test, the device automatically
switches to the conducting test (Mechanical Lifespan Test) after
10000 times of load test on kettle;when it is switched into the
manual test, the load test and the conducting test can be achieved
separately for satisfying the requirements of different samples.
The number of trials (up to 999999 times) can be preset. The device
automatically records the number of tests and the number of
conduction in the running. When the preset number of times is
reached, the device automatically shuts down.
Technical parameters:
No. | Item | Parameters |
1 | Power supply | AC220V 50Hz |
2 | Test station | 1 |
3 | Drive mode | adjustable-speed motor+ crank connecting link |
4 | Working stroke | 100mm |
5 | Working rate | 10 times/min(frequency control) |
6 | Total number of times | 1~999999 |
7 | load/conducting test times | 1~999999 |
8 | Clamp | Horizontal-vertical clamp |
9 | Load current | 1.1times of rated current. adjustable |
10 | Automatic test and manual test | Switchable |