Double Beam Atomic Absorption Spectrophotometer For Metal Analysis

Brand Name:Wayeal
Certification:ISO, CE
Model Number:AA2300
Minimum Order Quantity:1
Delivery Time:25 days
Place of Origin:Anhui, China
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Deuterium and Tungsten Lamp Equipped Double Beam Atomic Absorption Spectrophotometer AAS for Metal Analysis

Introduction of Atomic Absorption Spectrophotometer

Atomic absorption spectroscopy (AAS) is a spectroanalytical procedure for the quantitative determination of chemical elements using the absorption of optical radiation (light) by free atoms in the gaseous state. Atomic absorption spectroscopy is based on absorption of light by free metallic ions.
In analytical chemistry the technique is used for determining the concentration of a particular element (the analyte) in a sample to be analyzed. AAS can be used to determine different elements in solution, or directly in solid samples via electrothermal vaporization,and is used in pharmacology, biophysics, archaeology and toxicology research.


Parameters of Atomic Absorption Specphotometer

Double Beam Graphite AAS Atomic Absorption Spectrometer for Metal Analysis
Wavelength range(nm)185-900nm
Wavelength indication error(nm)±0.15nm
Wavelength repeatability(nm)≤0.05 nm
Spectral Bandwidth0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift±0.002/30min
Instantaneous noise(Abs)≤0.002 Abs
Flame Atomizer
Detection limitCu: ≤0.002μg/mL
RepeatabilityRSD≤0.25%
Graphite Furnace Atomizer
Detection limit(Graphite Furnance: Cd pg)≤0.3pg
RepeatabilityRSD≤1.5 %
Heating temperatureroom temperature -3000°C or so
Heating rate3000°C/s
Autosampler
Injection bits108
Linear>0.999
Injection volume1-200μL
Injection volume repeatability≤0. 1%
Result repeatability≤1.5%
Background correctionDeuterium lamp
Lamp position8


Features of Atomic Absorption Spectrophotometer AA2300
1. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
2. Full-reflection dual-beam optical path, high optical path stability
3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
4. 8 lamp holders preheat simultaneously to improve detection efficiency

Applications of Atomic Absorption Spectrophotometer
Food, medicine, environment, metallurgy, agriculture and disease control