Direct Differential And Flow Rate Pressure He Leak Tester Helium Leak Detector

Brand Name:Wayeal
Certification:CE
Model Number:V6
Minimum Order Quantity:1 Unit
Delivery Time:35 days
Payment Terms:T/T, VISA
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Introduction of Helium Leak Detector:


Helium leak detectors are used to detect and locate leaks in various systems, including vacuum systems, refrigeration systems, and pipelines. They work on the principle of mass spectrometry, which involves ionizing helium atoms and measuring their mass-to-charge ratio to detect the presence of leaks.

The basic working principle of a helium leak detector involves introducing helium gas into the system being tested and then using a mass spectrometer to measure the concentration of helium outside the system. If there is a leak in the system, helium will escape through the leak and be detected by the mass spectrometer.


Technical Parameters of Helium Leak Detector:


Direct Differential and Flow Rate Pressure He Leak Tester Helium Leak Detector
Differential Pressure SensorDisplay PrecisionThe value can be set to 0 to 4 decimal places
Sensor Range0Pa~±2000Pa
Sensor Error±0.1% F.S.
Direct Pressure SensorDisplay PrecisionThe value can be set to 0 to 4 decimal place
Recommended Test Pressure RangeStandard V5VH90BMechanical Pressure Regulating-100kPa~ -1kPa
CH050Mechanical Pressure Regulating5kPa~ 100kPa
CH050DMechanical Pressure Regulating5kPa~ 89kPa
CH600Mechanical Pressure Regulating10kPa~ 600kPa
CH600DMechanical Pressure Regulating5kPa~ 490kPa
CH1000Mechanical Pressure Regulating50kPa~ 1200kPa
CH1000DMechanical Pressure Regulating50kPa~ 890kPa
CH4000Mechanical Pressure Regulating50kPa~ 4000kPa
CH500Mechanical Pressure Regulating10kPa~ 5000kPa (seals leak detector)
ZF500Mechanical Pressure Regulating-100kPa~ -1kPa, 10kPa~ 500kPa
ZF2500Mechanical Pressure Regulating-100kPa~ -1kPa, 50kPa~ 2400kPa
Standard V6ZF600Mechanical Pressure Regulating-100kPa~ -1kPa, 10kPa~ 600kPa (Optional)
ZF2400Mechanical Pressure Regulating-100kPa~ -1kPa, 50kPa~ 2400kPa (Optional)
Sensor Error±0.25% F.S.
Display UnitTest PressurekPa,MPa,kg/cm2,psi,mbar,bar,Torr,mmH20,mmHg
Leakage RatePa,kPa,Pas,Pa.m3/s,mL/s,mL/min,mL/h,L/min,L/h,SCCM
Parameter Program Number64 Groups (1~64)
Test Beat Setting0~99 seconds, test time 1800 second
Power SupplyAA220V ±10%, 50Hz
Test Pressure SourceClean, dry, adequate flow, not less than 500KPa and 100KPa above the test pressure pressure source

Diamension


Standard V5330mm*222mmm*448mm
Standard V6321mm*205mm*460mm
Modular160mm*268mm*273mm
Weight20kg

Applications of Helium Leak Detector:


Vacuum systems: Helium leak detectors are used to test the integrity of vacuum systems such as those used in semiconductor manufacturing, aerospace, and research facilities. They are used to detect leaks in vacuum chambers, valves, and other components of the system.


Automotive industry: Helium leak detectors are used to test the fuel tanks, radiators, and other components of automobiles. They are used to detect leaks in the fuel system, cooling system, and air conditioning system.



Methods of Helium Leak Detection (Helium Leak Detector)


Helium Vacuum Method

Helium Hood Method



Negative Pressure Method


Vacuum Chamber Helium Leak Detection and Recovery System (external filling)


Sniffer Method