CE Air Tightness Helium Leak Detector Refrigeration Production Line Used

Brand Name:Wayeal
Certification:ISO90001, CE
Model Number:Standard V5
Minimum Order Quantity:1 Piece
Delivery Time:15 Days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

CE Certificated Refrigeration Production Line Used Air Tightness Helium Leak Detector

Description of Air Tightness Leak Detector

The Mass Spectrometer Leak Detector is a complete system for localization and measuring of leaks inside or outside of a product. This method uses so called tracer gas – helium, which is used to fill up the product connected to the detector. Helium leaks in/out of the tested product in to the detector where its partial pressure is measured and displayed on a screen.

Product Parameters of Air Tightness Leak Detector

CE Certificated Refrigeration Production Line Used Air Tightness Helium Leak Detector

Main Models Parameters

Differential Pressure Sensor

Display Precision

The value can be set to 0 to 4 decimal places

Sensor Range

±2000Pa

Sensor Error

±0.1%F.S

Sensor Pressure

13.8MPa

Standard

CH050

Mechanical Pressure Regulating

1~20kPa, 1~50kPa, 5~100kPa

CH050D

Electronic Pressure Regulation

1~20kPa, 1~50kPa, 5~100kPa

CH600


Mechanical Pressure Regulating


10kPa~ 600kPa

CH600D

Electronic Pressure Regulation

10kPa~ 600kPa

ZF600

Customized

-100~-1kPa, 50~2400kPa, 200~4000kPa

ZF2400

Customized

-100~-1kPa, 50~2400kPa, 200~4000kPa

Standard-Double Station

ZF2-600

Mechanical Pressure Regulating

10~600kPa

ZF2-600D

Electronic
Pressure Regulation

10~600kPa

Modular

CH600P

Mechanical
Pressure Regulating

10~600kPa

Direct Pressure Sensor

Sensor Error

+0.1%F.S.

Display Precision

The value can be set to 0 to 4 decimal places

Display Unit

Test Pressure

kPa,MPa,kg/cm2,psi,mbar. bar,Torr. mmH,0,mmHg

Leakage Rate

Pa,kPa,Pa/s,Pa.m3/s,mL/s,mL/min,mL/h. L ./min. L /h. SCCM

Parameter Program Number

64 groups (1~64)

Test Beat Setting

0 ~ 3600seconds

Power Supply

AC 220V+10%,50Hz

Test Pressure Source

Clean, dry, adequate flow, not less than 600KPa and 100KPa above the test pressure source

Environment Temperature

Working temperature: -5°C~40°C,Stock temperature: -20°C~70°C

Humidity

Below 80%RH, frostless

Overall Dimensions

Standard

321mmx440mmx206mm


Modular

191mmx249mmx268mm

Weight

Standard

20kgs


Modular

10kgs

Product Performance

1. Modular Integrated design
2. Automatic evacuation pressure and time setting, high leak detection efficiency;
3. It is suitable for direct pressure and flow rate leakage detection methods, and compatible with the use of single and multi-station requirements, to achieve one device to detect multiple products
4. Wireless remote-control function (optional);

Application of Air Tightness Leak Detector

It is widely used in production line industries such as refrigeration and air conditioning, automotive parts, carbonated beverage containers food packages and aerosol packaging, as well as in the manufacture of steam products, gas bottles, fire extinguishers, tire valves, and numerous other products including all vacuum systems.






China CE Air Tightness Helium Leak Detector Refrigeration Production Line Used supplier

CE Air Tightness Helium Leak Detector Refrigeration Production Line Used

Inquiry Cart 0