Wayeal IC6200 Ion Exchange Chromatography System for Cations and Anions Analysis


Introduction of Ion Exchange Chromatography Instrument

Ion chromatography is used for water chemistry analysis. Ion chromatographs are able to measure concentrations of major anions, such as fluoride, chloride, nitrate, nitrite, and sulfate, as well as major cations such as lithium, sodium, ammonium, potassium, calcium, and magnesium in the parts-per-billion (ppb) range. Concentrations of organic acids can also be measured through ion chromatography.


Features of Ion Exchange Chromatography Instrument

1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.

5. One-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning effect


Technical Data of Ion Chromatography Instrument

Wayeal IC6220 Laboratory Test Instruments 21 MPa Ion Chromatography System
System Parameter
Qualitative Repeatability≤0.5%
Quantitative Repeatability≤1.0%
Pump System
Flow Rate(0.001~10.000) mL/min
Pump Head Pressure Resistance(0 ~ 35) MPa
Flow Rate Setting Inaccuracy<0.1%
Flow Stability<0.1%
Pressure Display Accuracy0.01Mpa
Pressure Pulsation<0.5%
Conductivity Detector
Baseline Noise≤0.1%FS
Baseline Drift≤0.5%FS
Minimum Detectable Concentration (Cl)≤ 0.0002μg/mL
Minimum Detection Concentration (Li)≤ 0.0001μg/mL
Conductivity Cell Volume≤ 0.6μL
Conductivity Detection Range0-15000 μS/cm
Detector Resolution0.00238nS/cm
Conductivity Cell Temperature Setting Error±0.01°C
Resolution of Conductivity Cell Temperature Display0.001°C
Suppressor
Constant Current Source Range0-500mA in 0.1mA increments
Column Oven
Temperature RangeRoom temperature +5°C~85°C
Control Temperature Stability≤ 0.1°C
Autosampler
Number of Sample Vials≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5μL)

Syringe SizeStandard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop Size

Standard: 100μL; optional: 20μL, 50μL, 200μL

Linearity>0.999
Cross-contamination<0.01%

Eluent Generator

Flow Rate Range0.001 to 3.000mL/min
Eluent Concentration RangeKOH, MSA-0.1 to 100mM
Concentration Accuracy0.1mM
Original Concentration of Electrolyte25% KOH/MSA
Volume of Electrolyte1000mL
Maximum Working Pressure21MPa (3000psi)
Gradient Accuracy1.5%

Industry Application

Some typical applications of ion chromatography include:

  • Drinking water analysis for pollution and other constituents
  • Determination of water chemistries in aquatic ecosystems
  • Determination of sugar and salt content in foods
  • Isolation of select proteins