High Precision Liquid Chromatography Instrument System In Phytochemical Analysis

Brand Name:Wayeal
Certification:ISO, CE
Model Number:LC3200
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

HPLC Machine High Precision Liquid Chromatography Instrument System in Phytochemical Analysis

Introduction of Liquid Chromatography Instrument


High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the mobile phase) at high pressure through a column with chromatographic packing material (stationary phase). The sample is carried by a moving carrier gas stream of helium or nitrogen. HPLC has the ability to separate, and identify compounds that are present in any sample that can be dissolved in a liquid in trace concentrations as low as parts per trillion. Because of this versatility, HPLC is used in a variety of industrial and scientific applications, such as pharmaceutical, environmental, forensics, and chemicals.


Technical Parameters of Liquid Chromatography Instrument


HPLC Machine High Precision and Efficiency Liquid Chromatography System in Phytochemical Analysis
Physical Specification
Power Requirements220V,50HZ
Ambient Temperature4-40℃
Ambient Humidity20-85% relative humidity(non-condensing)
System
Qualitative repeatability(Retention time)RSD≤0.3%
Quantitative repeatability(Area)RSD≤0.6%
Pump
Flow Rate Range0.0001-10.000mL/min( increments :0.0001 mL/min)
Max Operating Pressure42MPa
Pressure Pulsation<0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Accuracy±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow PrecisionRSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient Accuracy±1%
Column Oven
Temperature Setting Range5 °C ~ 85 °C
Temperature Stability≤0.2°C/h
Temperature Controlling Precision±0.1 °C
Autosampler
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity>0.999
Cross Contamination(Carry Over)<0.01%
Sample Capacity120 Samples( 1.5ml vials)
Syringe250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop20μL( Standard, with 50μL, 100μL, 200μL optional)

FLD Detector

Noise1×10-5 Fu
Drift≤2×10-4Fu/30min
LOD5.0×10-10g/mL (naphthalene/methanol)
Wavelength Range200-650nm
Wavelength Reproducibility±0.2 nm
Linearity≥1.0×104



Performance of Liquid Chromatography Instrument

1. Built-in degasser to meet both high-pressure pump and feeder cleaning fluid degassing.


2. With local deploymeet and network deployment capabilities to meet the needs of users of different sizes.


3. Provide two-way "250mm column+protection column" installation position, to meet the majority of user needs.


4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.


Product Application

Food, medicine, chemical industry, agriculture, etc.




China High Precision Liquid Chromatography Instrument System In Phytochemical Analysis supplier

High Precision Liquid Chromatography Instrument System In Phytochemical Analysis

Inquiry Cart 0