42MPa Isocratic High Pressure HPLC Liquid Chromatography System in Pharmaceutical Industry

Description of HPLC Liquid Chromatography Instrument

High-performance liquid chromatography (HPLC) is a technique in analytical chemistry used to separate the components in a mixture, and to identify and quantify each component. It was initially discovered as an analytical technique in the early twentieth century and was first used to separate colored compounds.


Parameters of HPLC Liquid Chromatography Instrument

Manufacturer:Wayeal
Product Name:Liquid Chromatography Instrument
Working Power Supply220V, 50Hz
Ambient Temperature10~40°C
Relative Humidity20~85%
Qualitative Repeatability≤0.2%
Quantitative Repeatability≤0.4%
High Pressure Constant Flow Pump
Flow Rate Range0.001~10.000mL/min
Setting Step0.001mL/min
Pressure Range0~42MPa
Pressure Pulsation0.1MPa
Flow Rate Set Error±0.2%
Flow Rate StabilityRSD≤0.06%
Gradient Error±1%
Column Oven
Temperature Control Range4~85°C
Temperature Stability±0.02°C
Temperature Setting Resolution0.1°C
Autosampler
Injection Volume Repeatability<0.5%RSD
Linearity>0.9999
Cross Contamination<0.002%
Injection Volume Accuracy Error±1%
Sample Positions120
Injection Volume1~100μL
UV Detector
Baseline Noise≤2.0*10-6Au
Baseline Drift≤1*10-5Au/h
Mini Detection Concentration≤3.0*10-9g/mL (naphthalene/methanol)
Spectral Range188~900nm
Wavelength Error≤±0.1nm
Wavelength Repeatability≤±0.1nm
Linearity Range≥103
DA Detector
Baseline Noise≤4*10-5Au
Baseline Drift≤3*10-5Au/h
Mini Detection Concentration≤2*10-8g/mL
Spectral Range190~800nm
Wavelength Error≤±0.1nm
Wavelength Repeatability≤±0.1nm
Linearity Range≥ 104
ELS Detector
Baseline Noise≤ 0.0037mV
Baseline Drift≤ 0.0026mV/30min
Evaporation Gas Flow Range(0 ~ 3) SLM
Atomization Temperature RangeRoom temperature ~ 90℃
Evaporation Temperature RangeRoom temperature~110℃
Detection Chamber Temperature RangeRoom temperature~60℃
Input Air Pressure(4 ~ 7) bar
FL Detector
Baseline Noise≤ 5×10-6 FU
Baseline Drift≤ 2 × 10-5 FU/30min
Spectral Range(200 ~ 650) nm
Wavelength Error± 0.1 nm
Linearity Range≥ 104
RI Detector
Detection Range0.25 ~ 512 μRIU
Linearity Range≥ 600 μRIU
Response Time0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec;
Cell Volume8μL


Performance of HPLC Liquid Chromatography Instrument
1. Customized high-precision gradient valves, which guarantee extremely high gradient repeatability.

2. Two-stage suspension technology high-pressure constant-flow pump, which improves the system life, reduces the wear and tear of seals, and relieves customers of usage costs.

3. Provide two-way "250mm column+protection column" installation position, to meet the majority of user needs.

4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.



China 42MPa Isocratic High Pressure HPLC System In Pharmaceutical Industry supplier