HPLC Chromatografia System High Performance Liquid Chromatography in Pesticide Residue Analysis
Description of High Performance Liquid Chromatography Instrument

High-performance liquid chromatography (HPLC) is an important analytical method commonly used to separate and quantify components of liquid samples. In this technique, a solution (first phase) is pumped through a column that contains a packing of small porous particles with a second phase bound to the surface. The different solubilities of the sample components in the two phases cause the components to move through the column with different average velocities, thus creating a separation of these components. The pumped solution is called the mobile phase, while the phase in the column is called the stationary phase.

Parameters of High Performance Liquid Chromatography Instrument

Binary Pump Analytical HPLC Machine High Performance Liquid Chromatography Instruments
Physical Specification
Power requirements220V,50HZ
Ambient temperature4-40℃
Ambient humidity20-85% relative humidity(non-condensing)
System
Qualitative repeatability(Retention time)RSD≤0.3%
Quantitative repeatability(Area)RSD≤0.6%
Pump
Flow rate range0.0001-10.000mL/min( increments :0.0001 mL/min)
Max operating Pressure42MPa
Pressure pulsation<0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow accuracy±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow precisionRSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient accuracy±1%
Seal washWith programmable on-line seal wash module
Column Oven
Temperature setting range5 °C ~ 85 °C
Temperature stability≤0.2°C/h
Temperature controlling precision±0.1 °C
Autosampler
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity>0.999
Cross Contamination(Carry Over)<0.01%
Sample Capacity120 samples( 1.5ml vials)
Syringe250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop20μL( Standard, with 50μL, 100μL, 200μL optional)
DAD Detector
Noise1.5×10-5Au
Drift≤1×10-3Au/h
LOD5.0×10-9g/mL (naphthalene/methanol)
Wavelength range190-800nm
Wavelength accuracy≤±1 nm
Wavelength reproducibility≤±0.1 nm
Linearity≥1.0×104

Characteristics of High Performance Liquid Chromatography Instrument
1. Customized high-precision gradient valves, which guarantee extremely high gradient repeatability.


2. Seamlessly linked with the workstation, global set of components, high-precision metering pump, greatly enhance the accuracy of the injection.


3. Heating-cooling two way air bath temperature control, gentle control, uniform heat, high stability.


4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.