

Add to Cart
185-910nm AAS Machine Atomic Absorption Spectrophotomter for Metal
Analysis
Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectrometry (AAS) detects elements in either
liquid or solid samples through the application of characteristic
wavelengths of electromagnetic radiation from a light source.
Individual elements will absorb wavelengths differently, and these
absorbances are measured against standards
Parameters of Atomic Absorption Spectrophotometer AA2300
185 - 910nm AAS Atomic Absorption Spectrophotometer For Metal Analysis | |
Wavelength range(nm) | 185-900nm |
Wavelength indication error(nm) | ±0.15nm |
Wavelength repeatability(nm) | ≤0.05 nm |
Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, and 2.0nm |
Zero Drift | ±0.002/30min |
Instantaneous noise(Abs) | ≤0.002 Abs |
Flame Atomizer | |
Detection limit | Cu: ≤0.002μg/mL |
Repeatability | RSD≤0.25% |
Graphite Furnace Atomizer | |
Detection limit(Graphite Furnance: Cd pg) | ≤0.3pg |
Repeatability | RSD≤1.5 % |
Heating temperature | room temperature -3000°C or so |
Heating rate | 3000°C/s |
Autosampler | |
Injection bits | 108 |
Linear | >0.999 |
Injection volume | 1-200μL |
Injection volume repeatability | ≤0. 1% |
Result repeatability | ≤1.5% |
Background correction | Deuterium lamp |
Lamp position | 8 |
Features of Atomic Absorption Spectrophotometer AA2300
1. Stability: Double-beam system can automatically compensate the
light source drift and wavelength drift caused by the variation of
temperature (with the function of the eliminating the affection of
wavelength drift on the base line stability) and electronic circuit
drift so as to reach a good basic line stability.
2. Flame instrument 8-level safety interlock: with a complete set of
safety interlock systems, multiple pressure monitoring, automatic
safety protection functions, acetylene leakage detection.
3. High energy optical path: A total reflection system is adopted
to eliminate color difference in full range. By means of chemical
conversion, a round light spot of the light source becomes a long
light spot, which enters into the slit. Therefore the light flux of
double beam is enhanced.
4. Atomizer: high-efficiency glass, all-plastic, stainless steel
atomizer
5. Multi-functional analysis mode: for methods of flame absorption,
flame emission, graphite furnace atomic absorption and hydride
generation.
Applications of Atomic Absorption Spectrophotometer
Many elements, especially the emblematic elements, are essential
nutrients for the growth and development of living organisms.
However, some elements, especially heavy metals, can become toxins
if absorbed in excess. Therefore, the atomic absorption
spectrophotometer has been widely developed in the field of
agriculture, and has now become a routine analytical technique and
a national standard for the determination of certain elements in
the analysis of soil, fruits and vegetables, food and feed.