Laboratory Use High Pressure Ion Chromatography Instrument 35Mpa

Brand Name:Wayeal
Certification:ISO, CE
Model Number:IC6200
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Laboratory Use High Pressure Ion Chromatography Instrument 35Mpa

Introduction of Ion Chromatography Instrument

Ion chromatography instrument is a kind of high performance liquid chromatography, so it is also called high performance ion chromatography (HPIC). Its resin has high cross-linking and low exchange capacity, and the injection volume is very small.


Characteristics of Ion Chromatography Instrument

1. Intergrated design and compact structure, minimizing connections between components.
2. 7.0" high brightness LCD touch operation interface, synchronized with the chromatography workstation, clearly displays the working statusOne-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning performance.
3. One-touch maintenance": one-touch operation, the system can realize automatic maintenance of the instrument without manual operation, extending the service life of instrument.
4. Full PEEK pump and electric injection valve.

5. One-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning perforamnce.


Technical Data of Ion Chromatography Instrument

In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector
System Parameter
Qualitative Repeatability≤0.5%
Quantitative Repeatability≤1%
Pump System
Flow Rate(0.001~10.000)mL/min
Pump Head Pressure Resistance(0 ~ 35) Mpa
Flow Rate Setting Inaccuracy<0.1%
Flow Stability<0.1%
Pressure Display Accuracy0.01Mpa
Pressure Pulsation<0.5%
Conductivity Detector
Baseline Noise≤0.1%FS
Baseline Drift≤0.5%FS
Minimum Detectable Concentration (Cl)≤0.0002μg/mL
Minimum Detection Concentration (Li)≤0.0001μg/mL
Conductivity Cell Volume≤ 0.6μL
Conductivity Detection Range0-15000μS/cm
Detector Resolution0.00238nS/cm
Conductivity Cell Temperature Setting Error±0.01°C
Resolution of Conductivity Cell Temperature Display0.001°C
Suppressor
Constant Current Source Range0-500mA in 0.1mA increments
Column Oven
Temperature RangeRoom temperature +5°C~85°C
Control Temperature Stability≤ 0.1°C
Autosampler
Number of Sample Vials≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5μL)

Syringe SizeStandard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop SizeStandard: 100μL; optional: 20μL, 50μL, 200μL
Linearity>0.999
Cross-contamination<0.01%
Eluent Generator
Flow Rate Range0.001 to 3.000mL/min
Eluent Concentration RangeKOH, MSA-0.1 to 100mM
Concentration Accuracy0.1mM
Original Concentration of Electrolyte25% KOH/MSA
Volume of Electrolyte1000mL
Maximum Working Pressure21Mpa (3000psi)
Gradient Accuracy1.5%

Industry Application


Environment, food, medicine, agriculture, grain and oil, and chemical industry