Manufacturing, installation and commissioning of reverse osmosis
water treatment equipment:
Users should monitor the whole process quality and process of
manufacturing process equipment according to the design
requirements, and grasp the quality assurance of selected materials
and components.
In the process of equipment installation, the installation position
and physical and chemical indexes of instruments and filling
materials (filter media, resin, hollow balls, etc.) are strictly
located and inspected.
In the debugging process, the additives and consumables used in the
operation process should be tested qualitatively and
quantitatively. Special attention should be paid to the
compatibility of PAC, PAM, scale inhibitor, etc., and the suitable
operating consumables for the system should be selected through
tests.
Basic principle of reverse osmosis:
When two different solutions of pure water and brine are half
permeable between the membrane, the pure water with lower
concentration will permeate into the brine. The liquid level
difference generated by the equilibrium state is called osmotic
pressure. If enough pressure is applied to the surface of the salt
water (i.e. greater than the osmotic pressure), the water will flow
in the opposite direction. This phenomenon is called reverse
osmosis.
Technical Specifications of RO Water Treatment System
1000LPH Reverse Osmosis System | |
Model | JFRO-1000L |
Host Size | 1000x600x1600mm (can be customized) |
Power | 2.2KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 2000L/h |
Outlet Flow | 1000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 4 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP (Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP (Optional) |
Pipe Material | U-PVC, Stainless steel (Optional) |
The instrument (sensor) parameters of the water treatment system
must be calibrated every 3-6 months to ensure the accuracy of
equipment parameters. Because of the difference of surface water
sources, the types of operating problems of reverse osmosis
equipment are not the same in different places. Therefore, users
should carefully analyze the running status of their own system.
Especially in the characteristics of membrane pollution and system
cleaning should be explored according to the actual situation to
find out the solution to the problem suitable for the system.
For the outage protection process of reverse osmosis system, if
conditions exist, it is recommended to adopt a suitable way for
long-term protection. Avoid physical damage of reverse osmosis
membrane caused by frequent start-stop under short-term protection
or low pressure flushing conditions.
To sum up: the operating conditions of the reverse osmosis system
with surface water as the water source are more complex than those
of the underground water source. In order to achieve good operation
effect, it is necessary to check the design, manufacture and
operation of the equipment. Especially the optimization of the
operating conditions and the management of the operating system are
the key to the health of the equipment.
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter
(quartz sand filter) → Activated carbon filter → Soft water
processor → Precision filter → High pressure pump → Primary reverse
osmosis (RO) device → Purified water tank → High pressure pump →
Two Stage reverse osmosis → ultraviolet sterilization device →
water point.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and
softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean
source, etc.