1T/H One Stage Reverse Osmosis Filter System FRP Pure Water Purification Plant

Manufacturing, installation and commissioning of reverse osmosis water treatment equipment:

Users should monitor the whole process quality and process of manufacturing process equipment according to the design requirements, and grasp the quality assurance of selected materials and components.

In the process of equipment installation, the installation position and physical and chemical indexes of instruments and filling materials (filter media, resin, hollow balls, etc.) are strictly located and inspected.

In the debugging process, the additives and consumables used in the operation process should be tested qualitatively and quantitatively. Special attention should be paid to the compatibility of PAC, PAM, scale inhibitor, etc., and the suitable operating consumables for the system should be selected through tests.

Basic principle of reverse osmosis:
When two different solutions of pure water and brine are half permeable between the membrane, the pure water with lower concentration will permeate into the brine. The liquid level difference generated by the equilibrium state is called osmotic pressure. If enough pressure is applied to the surface of the salt water (i.e. greater than the osmotic pressure), the water will flow in the opposite direction. This phenomenon is called reverse osmosis.

Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
ModelJFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)


























The instrument (sensor) parameters of the water treatment system must be calibrated every 3-6 months to ensure the accuracy of equipment parameters. Because of the difference of surface water sources, the types of operating problems of reverse osmosis equipment are not the same in different places. Therefore, users should carefully analyze the running status of their own system. Especially in the characteristics of membrane pollution and system cleaning should be explored according to the actual situation to find out the solution to the problem suitable for the system.

For the outage protection process of reverse osmosis system, if conditions exist, it is recommended to adopt a suitable way for long-term protection. Avoid physical damage of reverse osmosis membrane caused by frequent start-stop under short-term protection or low pressure flushing conditions.

To sum up: the operating conditions of the reverse osmosis system with surface water as the water source are more complex than those of the underground water source. In order to achieve good operation effect, it is necessary to check the design, manufacture and operation of the equipment. Especially the optimization of the operating conditions and the management of the operating system are the key to the health of the equipment.

Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.



Photos of reverse osmosis water treatment system












FAQ:

1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

Model 4040 is designed by 0.25m3/h

Model 8040 is designed by 1-1.2m3/h

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3.What are the multi-way control valves?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.