Product introduction of RO Water Treatment System
When a pressure greater than the osmotic pressure is applied to the
brine side of the membrane, the direction of water flow is
reversed, and the water in the brine flows into the freshwater
side, a phenomenon called reverse osmosis (reverse osmosis,
abbreviated as RO). It is pretreated first and then treated with
RO. Through these treatments, 99% of dissolved salts and harmful
substances such as particles, colloids, organic impurities, heavy
metal ions, bacteria, viruses and heat sources can be removed. The
desalination rate of the system reaches 96-98%, and the
conductivity of the effluent is ≤ 10μ S/cm.
The basic working principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to
a pressure of 6-20 kg, the raw water permeates through the reverse
osmosis membrane with a pore size of only 0.0001 microns under the
action of pressure. Chemical ions, bacteria, fungi, and virions
cannot pass through, and are discharged with wastewater. Only water
molecules and solvents with a volume of less than 0.0001 microns
are allowed to pass through.
Technical Specifications of RO Water Treatment System
Model | JFRO-80T |
Host Size | 7200x2000x2200mm (can be customized) |
Power | ≈110KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 1.2~1.5MPa |
Recovery Rate | 75% |
Designed Water Inlet | 105t/h |
Outlet Flow | 80t/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304/Carbon Steel (Optional) |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 84 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 14 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Application fields of RO water treatment system:
1. Preparation of pure water and high-purity water required for
electronic industry production such as kinescope glass bulbs,
liquid crystal displays, circuit boards, computer hard disks,
integrated circuits, chips, monocrystalline silicon semiconductors,
etc.
2. Preparation of demineralized water and demineralized pure water
for thermal power and thermal power boilers and low-pressure boiler
feed water.
3. Preparation of medical infusions, injections, pharmaceuticals,
pure water for biochemical products, medical sterile water and pure
water for artificial kidney dialysis required by the pharmaceutical
industry. Preparation of drinking pure water, distilled water,
mineral water, alcoholic brewing water and pure water for blending
in the beverage (including alcohol) industry.
4, sea water, brackish water to prepare domestic water and drinking
water. To prepare pure water for surface coating, cleaning and
coating glass of electroplating, storage battery, automobile,
household appliances and building materials products; de-hardening
and desalinating water required for textile printing and dyeing
process.
5. The petrochemical industry, such as chemical reaction cooling
water; pure water for chemical agents, fine chemicals, and
cosmetics manufacturing. High-quality water supply network system
and swimming pool water purification for hotels, buildings and
communities.
Features of RO Water Treatment System
(1) The reaction rate is fast and the processing time is short.
(2) It has a wide range of applications, and has a good treatment
effect on refractory organic compounds containing azo, carbon
double bonds, nitro, and halogenated structures.
(3) The process is simple, the service life is long, the operating
cost is low, the operation and maintenance are convenient, and the
treatment effect is stable.
(4) The removal rate of chromaticity and COD is high, and the
biodegradability of RO concentrated water is improved.
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter
(quartz sand filter) → Activated carbon filter → Soft water
processor → Precision filter → High pressure pump → Primary reverse
osmosis (RO) device → Purified water tank → High pressure pump →
Two Stage reverse osmosis → ultraviolet sterilization device →
water point.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and
softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean