UL 1581 Vertical / Horizontal Wire Flame Test Apparatus Cables And Wires Flame Resistance Test

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN7711
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

UL 1581 Vertical/Horizontal Wire Flame Test Apparatus Cables and Wires Flame Resistance Test


Product information:


This flammability test chamber meets the requirements of UL1581 and UL94 flame test. The effects of flames in the early stages of fire on electrical and electronic products are used to assess the degree of fire hazard through simulation techniques. It is mainly used for 1080 VW-1 (vertical-specimen) flame test and 1100 horizontal-specimen/ FT2 flame test on finished wires and cables or cords, to evaluate the ability of wires, cables or flexible cords to spread flame to nearby flammable materials when it is on fire.

The equipment adopts PLC control system, touch screen humanized operation interface, black background, multi-function flame gauge; the chamber body is made of stainless steel, the observation window is large; the original imported flame control system to make the flame adjustment become simple; and it has stable performance and convenient operation.


Technical parameters:


Flames225W&500W
StandardUL1581, UL94
Power Supply220V/ 50Hz
Operation systemMitsubishi PLC control, VEINVIEW7” touch screen
Ignition ProcessAutomatic
BurnerDiameter: 9.5mm ± 0.5mm, Length:100mm, Original imported, in line with ASTM 5025 standard
Burning Angles0°, 20°, 45° adjustable
Flame Height20mm~125mm±1mm adjustable
Timing Device9999X0.1s can be preset
ThermocoupleU.S. original Omega Φ0.5mm armored stainless steel sheathed K-type thermocouple
Temperature Measurement Distance25±1mm/55±1mm
Temperature Measurement RangeMAX 1100°C
Flame Test

Adopt original imported flowmeter, the flow rate is adjustable, the accuracy is 1%, the following are the reference values of each test:

500W: 965±30ml/min, 54±2S(100-700°)

Reference values of UL1581 power, flame height, temperature measurement time and flow:

225W: (16.5mm)/84±2S 405 ±10mL/min& 45±5 mm water

500W: 125mm(40mm)/54±2S

A: 965 ±30mL/min&125±25 mm water

B: 385 ±15mL/min&552±100 mm water

C: 300 ±10mL/ min&600±125 mm water

Copper Weight

Ф9mm±0.01mm Copper head, Cu-ETP purity:99.96%,

10 ± 0 .05 g

Gas CategoryMethane
Test Space4m³
Chamber and AppearanceStainless steel chamber, black matt background with exhaust fan
Size and weightW*D*H=1.7*1.3*2.4m, about 350kg
Features:
  • Mitsubishi PLC control and VEINVIEW7” touch screen opetaion, ensure the operation is humanized
  • Original imported flame control system to make the flame adjustment become simple
  • Automatic ingition process to ensure the operator's safety
  • Original imported flowmeter and Omega themocouple ensures the testing accuracy