System overview:


The horizontal freezer slide lid opening and closing test machine is designed and manufactured according to Chapter 5.3.3.2 of ISO 23953-2:2015(E) and customized requirements of customers. It is used for the opening and closing durability test of the horizontal freezer slide lid, also used for lid sliding actions during the energy efficiency performance test of the freezer. It is a dedicated fully automated testing equipment, which is suitable for testing departments such as testing and certification agencies, factory laboratories, etc.

This equipment adopts PLC intelligent control with mature technology, equipped with 2 sets of position-adjustable action actuators and mechanical fixture structures to clamp the handles on the surface of the freezer slide lids (also come with 2 sets of vacuum suction cups to meet the needs of different samples). At the same time, it is equipped with a color LCD touch screen as standard, which can preset the opening stroke, opening and closing speed, and opening pause time and interval time, so as to truly simulate the opening and closing of the freezer lid by hand, to achieve an intelligent control method, one machine with multiple functions.


Equipment principle:


Controlled by PLC, operated by intelligent touch screen, the servo motor drives the manipulators, and drives the clamp to hold the handle of the freezer lids (or vacuum suction cups to suck the surface of the freezer lids), so that it can open and close the lids in a reciprocating linear motion.


Process flow:

Refrigerator  
StepContentExecution time
Step 1Open the lid and close3min
Step 2Open the lid to >80%1s
Step 3Keep opened13s
Step 4Close the lid1s
Step 5Keep closed I5min45s
Step 6Repeat steps 2-511h54min
Step 7Keep closed II12h
Freezer  
Step 1Open the lid and close3min
Step 2Open the lid to >80%1s
Step 3Keep opened4s
Step 4Close the lid1s
Step 5Keep closed I9min54s
Step 6Repeat steps 2-511h50min
Step 7Repeat closed II12h

The structure of the testing machine as shown in the figure below, the overall frame structure is adopted, and the sample is placed on the bottom plate of the equipment, so that the relative movement is the internal stress, and the shaking of the equipment is reduced. Two column structures are installed on the bottom plate, and the each column contains one set of lid opening and closing mechanism as shown in Figure 1. At the same time, the freezer positioning fixture is installed on the bottom plate, which can clamp and fix the front, rear, left, right, and rear sides of the freezer. Applicable samples are as shown in Figure.



Technical Parameters:


No.ProjectContent
1Input powerAC220V 50HZ, 5kW
2Electrical controlMitsubishi PLC intelligent control
3Operation interfaceWeinview 7-inch color man-machine interface touch screen operation
4Drive modeServo motor + precision sliding platform
5Range of samples

The same types of samples shown as in Figure 2

WDH=(60~214cm)×(45~70cm) ×(70~90cm)

6Test itemsFreezer slide lid durability test
7Test station1 station, can test a horizontal freezer with left and right slid lids
7ColumnThe position of the slid lid can be matched by adjusting the height position of the manipulator and the position of suction cup on the column
8Robotic arm2 sets of manipulators for opening and closing lids alternately, adjustable clamp positions (that is, adjustable in length and height directions), suitable for freezer slide lids of different widths
9Adsorption structure

1. Mechanical clamping fixtures, toggle type, 2 sets

2. Vacuum suction cups, 2 sets

10Lid opening stroke0-500mm±0.1mm can be set on touch screen, adjustable on both sides
11Lid first opening time3min
12Lid opening pause time0-9999S, can be set on touch screen
13Lid closing pause time I0-99h59m59s, can be set on touch screen
14Lid closing pause time II0-99h59m59s, can be set on touch screen
15Lid open/close speed10-600mm/s, can be set on touch screen
16Freezer auxiliary positioning mechanism2 sets, which can be fixed the two sides of the freezer
17Equipment frame

Match the largest sample range, sample is installed on bottom plate of the equipment. There are three bottom plates for sample installation, the three bottom plates can be combined and split easily to adapt to specimens of different widths. Shown as following:


18Power failure memoryThe system has a power failure memory function, which can continue to accumulate parameter actions and times before power failure
19ProtectEmergency stop, leakage, short circuit, overload and other safety protection
20The overall size and weight of the testing machineFrame WDH: Width 1800*Depth 1200*Height 1400mm, about 350kg