IEC 60598-1 Luminaries Adjustment Test Equipment Lamp Adjustment
Torsion Device Rotation Angle 360°
Standard and Clause For Luminaries Adjustment Test Equipment:
This lighting adjustment test equipment matches the requirements of
clause 4.14.3 of IEC 60598-1, mainly used for the lamp adjustment
device’s torsion, and bending test of the table lamps, floor lamps
and the lamps which are for professional use (such as a plotter
lamps).
Product Information For Luminaries Adjustment Test Equipment:
a) Adjusting devices and means of adjustment, for example joints,
hoisting devices, adjusting brackets or telescopic tubes, shall be
so constructed that cords or cables are not pressed clamped,
damaged or twisted along the longitudinal axis by more than 360°
during operation.
If a luminaire has more than one joint the 360° limit applies to
each joint if they are not too close together. Each case needs to
be judged on its own merits.
Compliance is checked by the following test and inspection:
The adjusting device, equipped with the appropriate cable or cord
shall be operated in accordance with Table 4.5. A cycle of
operation is a movement from one extreme of the range to the other
and back to the starting position. The rate of movement shall not
causethe device to heat appreciably and shall not exceed 600 cycles
per hour.
For electromechanical contact systems, this test is conducted
simultaneously with theelectrical connection test of 4.11.6.
During the test the values according to Table 5.2 shall not be
exceeded.
After the test, not more than 50 % of the strands in a conductor
shall be broken nor shall there be any serious damage to the
insulation, if any, of the flexible cord. The cord or cable shall
be subjected to, and shall satisfy, the insulation resistance and
high-voltagetests specified in Section 10.
Ball-joints and the like, where the clamping means can be adjusted,
are tested with the joints only lightly clamped to avoid excessive
friction. lf necessary, the clamping areas arereadiusted during the
test.
For adjusting devices that consist of a flexible tube, the range of
adjustment for this test is normally 135° in both directions from
the vertical. However, where this adjustment cannot be achieved
without using unreasonable force, the flexible tube is bent only to
the positions where it will remain by itself.
b) Luminaires with a means of adjustment intended to be installed
within arm's reach, shall allow the operation of its intended
function without impairing the stability of the luminaire or
causing deformation of any part of the construction, nor cause
injury due totemperatures above those specified in Table 12.1.
Compliance is checked by manipulating or handling the luminaire, by
the means of adjustment as expected to represent normal use and by
measurement of the temperaturesduring the test of 12.4
c) For luminaires intended to be mounted within arm's reach, the
space surrounding anymeans of adjustment, except the light beam
aperture, up to 5 cm away irom the means of adjustment in any
direction, shall comply with the temperature limits for the means
ofadjustment, as specified in Table 12.1. The same temperature
limits apply also to anymeans of adjustment which are lit after the
positioning of the luminaire light beam aperture.
Technical Parameters For Luminaries Adjustment Test Equipment:
Power Supply | AC220V, 50HZ |
Bending /Rotation Angle | 0~360° (or 0~±180°) can be preset on touch screen |
Test Speed | 0 to 60 times / min, can be preset |
Test Cycles | 1~999999 can be preset |
Electrical Control | PLC & 7” touch screen |
Drive Mode | Stepper motor |
Operation Mode | Intelligent touch screen control (7 inches) |
Rotation Center Height | 1200mm |
Platform Liftable Stroke | 0-1000mm, manually adjustable by rotating the hand wheel |
Maximum Radius of Gyration of the Rotating Fixture | R500mm |
Test Station | One station |
Structure For Luminaries Adjustment Test Equipment:
The test equipment is coming with integrated PLC & touch screen, motor drive bending mechanism, sample installation platform. The bending angles, test speed and test cycle can be set on touch screen. Once the test is completed or failed, the test equipment will give out signal.