Home /Analyzers /

IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display

IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN9932
Minimum Order Quantity:1
Delivery Time:1 Month
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display


Applied Standards For Lifting Test Machine:


Conform to IEC 60598-2-17 clause 17.7.4. and IEC60598-2-23 Clause 7.4 and 7.5.


Technical parameters For Lifting Test Machine:


Capacity0~1T
Accuracy levelLevel 1
Control methodIt is controlled by microcomputer
Display methodElectronic LCD display
Power unitkgf, gf, N, kN, lbf
Stress unitMPa, kPa, kgf/cm2, lbf/in2
Displacement unitmm, cm, in
Display resolution0. 1N
Lifting stroke600mm
Platen size600*600mm
Software functionChinese and english are interchangeable
Shutdown modeOverload shutdown, emergency stop button, automatic shutdown of test piece destruction, automatic shutdown of upper and lower limit settings
Safety equipmentOverload protection, limit element protection device
Machine powerAC variable frequency motor drive controller
Computer systemHigh precision ball screw
Power supplyCan be customized
Machine weightAround 250KG
Performance characteristicsThe percentage break value can be set, the machine will stop automatically, and 4 different speeds can be selected when enter the menu. 20 results are available, the average of all test results and single results can be viewed.

Basic Operation Before Use Lifting Test Machine:


1 Please set the test parameters before starting the test, otherwise the system will use the last parameters by default.

2 Please check and save the parameters after setting (it will be automatically saved in some interfaces), and the system will automatically use the saved parameters when the system is turned on next time;

3 Gain 1 is related to the sensitivity of the sensor, and can be matched with the hardware dial switch;

4 The position of the red dial switch has changed, and the hardware zero position should be re-calibrated.

Troubleshooting and Maintenance For Lifting Test Machine:

Fault situationPossible CausesMethod of exclusion
Turn on the main switch of the instrument, the indicator light at the switch is not on.

Power is not entered

Check the rear power socket of the instrument.

Ask an electrician to check the repair power line

Check if the power station fuse is broken.

Press the F3 key and F4 key no action

Button failure

Damaged relay

Motor speed box damaged

Tighten the screws securing the circuit board

Replace relay

Replace motor speed box



China IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display supplier

IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display