IEC 1251 Constant Temperature And Humidity Chamber With PLC Control For Solar Panel Test


Product Information For Temperature And Humidity Walk-In Test Equipment:


Solar panel walk-in constant temperature and humidity test chamber is mainly designed and manufactured according to standards of IEC 60068-2-78, IEC 1251:1993, IEC 61730 and etc. It is used to test photovoltaic modules and determine the ability of modules to withstand long-term moisture penetration. The purpose is to determine the ability of modules to resist heat cycles and humidity-heat tests. It is also suitable for ESS high and low temperature cyclic stress screening test or constant test for electrical and electronic products and other products, parts and materials, and for quality and reliability testing of products, parts and materials under simulated temperature changes.

The test room adopts PLC intelligent central integrated control, touch screen display and operation, it is equipped with sample placement brackets, and a slope at the entrance of the test room. The samples are convenient to be moved and placed. The whole system is simple to operate, and the whole machine is beautiful and generous.


System Principle For Temperature And Humidity Walk-In Test Equipment:


The PLC is used to control the cooling of the compressor, the heating of the heat pipe and the humidification of the humidifier, cooperating with the indoor air duct to realize the control of the temperature and humidity in the chamber.

Forced circulation ventilation, balance temperature regulation method. The control system controls the output of the heater through the PID automatic calculation output according to the temperature point set by the system, and finally reaches a dynamic balance.



Technical Parameter For Temperature And Humidity Walk-In Test Equipment:


ItemSpecifications
NameSolar Panel Walk-in Constant Temperature and Humidity Test Chamber
ModelSN886-6000
Working studio size (mm)1500×2600×1500 W*D*H
Numbers of samples that can be placed5 pcs, Sample size not larger than 1200×2400×45 mm W*D*H
Chamber external size(mm)Approx.2000×2850×2720 W*D*H
Test RangeTemperature-40℃~+100℃
Humidity

20%~98%RH (Shown as following)


Heating and cooling rateRising rate≤1.6℃/min (full average)
Cooling rate≤1.0℃/min (full average)
Temperature fluctuation≤±0.5℃ (at steady state)
Temperature uniformity≤2℃ (at steady state)
Temperature deviation±2.0℃
Humidity Deviation

≤+2/-3%R.H. (when the humidity>75%R.H.)

≤±5%R.H. (when the humidity>≤75%R.H.)

Test contents1. Thermal cycle: cycle from -40°C±2.0°C to 85°C±2.0°C, the temperature change rate is less than 100°C/h, the constant temperature time is at least 10min, and one cycle does not exceed 6h
2. Humidity-heat test: 85°C±2.0°C, 85%±5%, test time 1000h
Noise≤75dB
WeightApprox. 2100KG
Test method applied

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

Note: The above performance indicators are measured at room temperature +25°C without samples.
MaterialInner wall materialSUS304# stainless steel plate
Outer wall materialCold rolled steel plate, pickling and phosphating advanced powder baking paint
Insulation materialrigid polyurethane foam + glass fiber
StructureAir duct partsCentrifugal fan; the air outlet can adjust the air volume, height and return air volume
DoorSingle open door, with handle-type non-reaction handle, the door is equipped with an observation window, lighting lamp, window/door frame anti-condensation electric heating device, Door size: SN886-4300: (approx.) 1.1*1.5M, SN886-5800 (approx.) 1.5*1.5M
Observation windowThe door with one conductive film explosion-proof tempered glass observation window (with anti-condensation function), window size: 500W×600H (mm)
FanLong axis centrifugal fan
Sample mounting rackWill be customized to match client’s sample
ImpellerUse stainless steel impeller imported from Taiwan
HeaterNickel-chromium alloy electric heater
Refrigeration CompressorFrench Tecumseh compressor

Evaporator


Fin type evaporator
Refrigerating methodMechanical compressor cascade
Cooling methodAir-cooling
Temperature control instrument10-inch smart LCD touch programmable controller
Lead holeΦ100mm, 1 pc, equipped with a special foam rubber plug (located on the left side of the chamber)

Program Control System For Temperature And Humidity Walk-In Test Equipment:


Controller10-inch smart LCD touch programmable controller
Temperature and humidity display accuracy0.01℃/ 0.1%RH
Touch-type high-resolution screenArbitrary setting of fixed conditions, program conditions, and setting of curing test name, serial number, etc.
Time range can be set0—999H59min
Programmable modeAt the same time, 120 groups of programs with different conditions can be set. In any group of programs, it can be divided into 1200 segments, and part of the number of segments can be intercepted arbitrarily to execute the cycle, or to perform cycle work of any section or group.
SafetyIt has a power-off memory device, which can continue to execute the remaining programs when the power is restored, and can be used as a machine appointment to execute the startup and machine running time.
ControlThe temperature rise and fall can be used for slope control, curve control, and have the function of self-correcting temperature and humidity reference points. It has the function of PID automatic calculation, which can reduce the convenience caused by manual setting.

Communication function

(Optional, cost is additional)

U disk interface, RS-232 interface, misoperation hardware lock (LOCK), computer communication software is provided
SettingSettings and all conditions are automatically locked by microcomputer
AlarmIf an error occurs during setting or operation, a warning signal will be provided
OutputThe controller has a recording signal port output, which can be connected to a temperature and humidity recorder and can output recording curves
InterfaceEquipped with standard RS-232 communication interface, long transmission distance, can be connected to PC for control and recording.

Chamber structure For Temperature And Humidity Walk-In Test Equipment:


The test chamber consists of a control cabinet, a chamber body, a sample mounting bracket and a slope.


China IEC 1251 Constant Temperature And Humidity Chamber With PLC Control For Solar Panel Test supplier

IEC 1251 Constant Temperature And Humidity Chamber With PLC Control For Solar Panel Test

Inquiry Cart 0