Parallel Intelligent Air Cooled Xenon Lamp Aging Test Chamber Touch Screen Control

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN884B
Minimum Order Quantity:1
Delivery Time:1 Month
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Parallel Intelligent Air-Cooled Xenon Lamp Aging Test Chamber Touch Screen Control


Product overview for Parallel Intelligent Air-Cooled Xenon Lamp Aging Test Chamber:


Complied Standards & Clauses: AATCCM16, ASTM-D4459, etc.


The control system is one of the most important systems of this equipment. It adopts a 7-inch full touch screen controller, comprehensive electromagnetic compatibility design and humanized menu design, and adopts the PLC program independently developed and written by the company and adaptive temperature control technology for temperature control. , which makes the operation of the equipment completely simple, and solves the problems of multiple parameter setting and temperature overshoot in the past PID control technology, and the temperature control effect is excellent.

Black panel temperature, air temperature, radiation intensity, water spray time, stop spray time, accumulated radiation energy, and test cycle times can be directly set and displayed. Microcomputer intelligent control, after setting the temperature, the instrument automatically controls the heating power and displays the heating status, the temperature control is accurate and stable. Over-temperature alarm and automatically cut off the heating power supply. The touch operation is extremely user-friendly, and the man-machine correspondence effect is very ideal.


Technical parameters for Parallel Intelligent Air-Cooled Xenon Lamp Aging Test Chamber:


ParameterDescription
Using environment requirements:Temperature 5℃~+22℃, humidity: ≤85%RH
Studio size400×750×300mm (D×W×H)
Dimensions950x950x1800mm (D×W×H)
Power(kw)10KW

Black panel temperature range

Light cycle

Dark cycle

45℃~110℃

40-90℃

25-50℃

Cabinet air temperature

Light cycle

Dark cycle

35-65℃

25-50℃

Relative humidity

1. Range: 20~95%R

2. Humidity accuracy: ≤±5%

Rainfall cycleSpray 18min/stop 102min; spray 12min/stop 48min
Spectrum wavelength290~2450nm wavelength band
Radiation intensity of xenon lamp400~1120W/m2
Xenon lamp tube power1.8KW (Q-LAB air-cooled full solar spectrum long-arc xenon lamp) 3pcs
Total Power of Xenon Lamp5.4KW, service life: 1200 hours
Black panel temperature

BST control range: 45-110°C (adjustable)

BPT control range: 50-90°C (adjustable)

Distance from arc center to sampleEffective exposure area within 200mm ≥ 2000cm2
TrayW500XD250MM, tilted 10 degrees
Accuracy rangeSetting/Indicating Accuracy: Temperature 0.1℃, Humidity 1%RH
Temperature and humidity sensorPlatinum resistance.PT100Ω/MV
Heating systemFully independent system, nickel-chromium alloy electric heating heater
Humidification systemExternal isolated, all stainless-steel shallow surface evaporative humidifier
Black panel temperatureBimetallic black panel thermometer
Temperature ControllerAdopt Teelong Kunlun network version touch screen and Xinjie PLC module control
Circulatory systemTemperature-resistant low-noise air-conditioning motor. Multi-blade centrifugal wind wheel
Outer box materialHigh-quality carbon steel plate, phosphating electrostatic spray treatment / SUS304 stainless steel matte line hairline treatment
Inner box materialSUS316 high-quality stainless-steel light plate
Sample holder materialSUS316 high-quality stainless-steel bar
Insulation of door frameHigh and low temperature aging resistant silicone rubber door seal
Number of racks

The number of samples is not less than 10, and the sample holder is 316 stainless steels

Sample placed on one layer

Sun eyesThe three sun eyes are designed by the German chip "Teelong" intelligent radiation induction loop system. Automatic correction of irradiation intensity setting value. High temperature resistance, high humidity resistance, shell 304 material design and production.
Standard configurationAnti-radiation glass window filter, 3 xenon lamp tubes
Safety protectionLeakage, short circuit, over temperature, water shortage, motor overheating, over current protection
Power supplyAC380V±10% 50±0.5Hz three-phase five-wire system

Performance characteristics for Parallel Intelligent Air-Cooled Xenon Lamp Aging Test Chamber:

1. Ventilation and cooling device: The ventilation and cooling system of the test chamber is automatically controlled by the temperature controller, and the intelligent mechanical air-cooling system is used to cool down in the chamber.

2. The control blackboard thermometer adopts wired transmission technology, which effectively improves the control accuracy.

3. Using optical fiber transmission to measure the radiation intensity of the xenon lamp, avoiding the problem of measurement error caused by temperature.

4. A black panel thermometer BPT or black standard thermometer BST is installed on the sample holder.

5. Device: In order to record the working time of each test, the equipment is equipped with a timer on the operation panel, which can control the equipment time, and the equipment will automatically shut down when the timing ends.

8. Protection device: In order to make the xenon arc lamp work normally without damage, the xenon lamp is automatically extinguished when the door is opened, and the whole machine stops working.


Structure and configuration for Parallel Intelligent Air-Cooled Xenon Lamp Aging Test Chamber:


1. Integral structure: composed of test chamber, heating//lighting/system/electrical control

2. Box material: A3 board with baking paint.

3. Cabinet liner: SUS316 stainless steel plate

4. Door: Silicone rubber tight seal.

5. Sample rack: made of all stainless steel, the fixed position of the sample is adjustable, and the standard stamping and forming sample

6. Controller: self-developed touch screen + PLC programmable touch screen controller "xenon lamp professional controller".

7. Convection: special motor for long axis

8. Device running timing controller

9. Black Panel Thermometer BPT or Black Standard Thermometer BST

10. Dedicated filters (light through glass windows or solarization filters)

11. Irradiance meter: intelligent automatic irradiation intensity compensation, automatic correction of irradiance





China Parallel Intelligent Air Cooled Xenon Lamp Aging Test Chamber Touch Screen Control supplier

Parallel Intelligent Air Cooled Xenon Lamp Aging Test Chamber Touch Screen Control

Inquiry Cart 0