IEC 60335 Clause 7 Dual Station Label Marking Abrasion Test Apparatus

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN1101
Minimum Order Quantity:1
Delivery Time:20 Days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

IEC 60335 Dual Station Label Marking Abrasion Test Apparatus


Standards For Dual Station Label Marking Abrasion Test Apparatus:


This label marking abrasion test apparatus conforms to IEC 60335-1 clause 7.14, IEC 60065:2014 clause 5.1, IEC 60950:2013 clause 1.7.11, IEC 60669-1 clause 8.9.


Technical parameters For Dual Station Label Marking Abrasion Test Apparatus:


Test stationsTwo stations
Test stroke10-60mm, adjustable(Manually adjustable)
Speed5-60 times /min, adjustable
Counter0-9999 adjustable
WeightTwo pieces of 10g, 20g,50g, 100g, 200g, 500g
VoltageAC 220V, 50Hz
Machine size:500*300*550mm

Maintenance Notes For Dual Station Label Marking Abrasion Test Apparatus:


1 The instrument must be placed on a stable surface before use.

2 It is not allowed to move the machine during use.

3 Select the appropriate power supply voltage, should not be too high, to avoid burning the instrument.

4 If the instrument works abnormal, please contact with us for timely processing.

5 The instrument must be used in a good ventilation environment.

6 Please add lubricating oil to the mechanical transmission part in time due to the large operating load of each component of the button mechanism.

7 After each test is completed, operator should clean the machine.

8 The control box part must be wiped with a dry cloth.


Troubleshooting For Dual Station Label Marking Abrasion Test Apparatus:


1 If the POWER is turned on, the instrument is not powered on or the power indicator is not light: if the power indicator is damaged, replace the indicator; if there is no power output at the power output terminal, please check the power cord or power socket-outlet.

2 If the power is turned on, the power indicator lights, but the machine does not work when operator presses the SWITCH button. Please check whether there is a disconnection. If there is a disconnection, please connect it in time. If there is no disconnection of the relay, indicating that the counter is damaged, the counter should be replaced in time.

3 When the number of times set on the counter is finished, but the motor does not stop working, indicating that the counter is damaged.

4 If the power indicator light is on but the counter has no display, it means that the counter is damaged and the counter needs to be replaced.


Configuration

No.:NameUnitQuantity
1Main deviceLabel Marking Abrasion Test ApparatusSet1
2AccessoryPetroleum spirit/ alcohol abrasion test fixturesPCS2
Rubber head abrasion test fixturesPCS2
Pencil abrasion test fixturesPCS2
Cotton clothPack1
Rubber headPCS2
PencilPCS2
3DocumentUser manualCopy1
Certificate of qualityCopy1
Warranty cardCopy1

China IEC 60335 Clause 7 Dual Station Label Marking Abrasion Test Apparatus supplier