Add to Cart
IEC60068 Table Type Xenon Lamp Simulated solar radiation Aging Test chamber
Standards & Clauses:
GB/T16422.3 -2014 / ISO 4892-3:2006 “Plastics-Methods of exposure to laboratory light sources-Part 3: Fluorescent UV lamps”
IEC60068-2-5 “Environmental testing -Part 2-5: Tests-Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing, IDT”
GBT2423.24-2013 “Environmental Testing-Part 2: Test Methods-Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing”
ASTMG155,ISO10SB02/B04,SAEJ2527,SAEJ2412
Technical Parameters:
Applied Standards | IEC60068, ASTMG155, ISO10SB02/B04, SAEJ2527, SAEJ2412 |
Effective exposure area | 1000cm³ |
Black board temperature range | RT+30℃-80℃ |
Condensation cycle | 40℃-60℃ |
Material | Stainless-steel board |
Dimension | 950*530*540mm |
Details
Irradiance setting range: Chinese lamps:
30W/m²~100W/m²(300nm~400nm) or 0.3W/m²~0.8W/m²(@340nm) or
0.5W/m²~1.5W/m²(@ 420nm)
Imported lamps: 30W/m²~120W/m²(300nm~400nm) or
0.3W/m²~1.0W/m²(@340nm) or 0.5W/m²~1.8W/m²(@420nm)
Product overview:
This instrument uses a UV extension filter that allows the passage of UV light below the cut-off point of natural sunlight (equivalent to sunlight without atmosphere), which simulates the full spectrum of sunlight in an optimal way, and through appropriate temperature control, to Comprehensively obtain the results of the damage of sunlight and temperature on polymer materials (material aging includes fading, loss of light, strength reduction, cracking, peeling, chalking and oxidation, etc.).
In days or weeks, this test chamber is capable of reproducing
damage from months or years of outdoor environments.
It is the most economical, compact, simple, reliable and
easy-to-operate xenon lamp aging test chamber, which is widely used
in the estimation and evaluation of material life in paint
coatings, automobiles, plastic products, wood products, rubber and
other industries.