IEC 60335 Single Station Cordless Kettle Base Plug Endurance Test Device
Standards & Clauses:
This apparatus conforms to IEC 60335-2-15: 2005, IEC 60335-2-3:2005 (Ed5. 1), IEC 60335-2-14: 2006, etc.
Main Parameters:
No. | Project | Parameter |
1 | Operation method | Touch screen control |
2 | Displacement | 0-160mm can be preset |
3 | speed | 0-18mm/s can be preset |
5 | Number of trials | 0~999999 can be preset |
6 | time | 0-999.9s can be preset |
7 | Fixture | Manipulator fixture |
8 | Load current voltage | 0-250V, 0-15A adjustable |
9 | Load and non-load test | Automatic switching |
10 | Test station | Single station |
11 | power supply | 220V 50Hz |
12 | Dimensions and weight | 83*50*104cm,150kg |
Product overview:
The apparatus is used to test the connection contacts of cordless
electric irons, cordless kettles, cordless coffee pots, and
cordless stirrers for household and similar purposes. The structure
should ensure that any electrical or mechanical failures in normal
use will not cause danger. Verify by plugging test.
Short-circuit the two conductive pins of the cordless electric
iron, cordless kettle, cordless coffee maker, and cordless blender.
The external load provides 1.1 times the rated current under the
rated voltage, and then the motor drives the lifting mechanism to
perform a certain number of plug life tests on the base at a rate
of 10 times/min. The sample shall be subjected to a certain number
of plug-in tests without power on. The device can be connected with
an external load or an optional built-in load. The number of tests
can be preset (up to 999999 times), and the number of tests and the
number of conductions will be automatically recorded during
operation. When the preset number is reached, the device will
automatically stop.
Application:
The appliance coupler of cordless appliances shall be constructed to withstand the stresses occurring during normal use, which is verified through insertion and withdrawn testing.