IEC 60884-1 Clause 11.5 Multitester Electrical Safety Tester


Product information:

This multitester electrical safety tester Conforms to IEC 60884-1:2013 clause 11.5, 17.1, 17.2, IEC 60669-1 clause 11.4, clause 16, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 10, 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.


Features:

■ Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards

■ Unlimited storage of test conditions and test results

■ Data can be copied via USB

■ Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast

■ High accuracy: safety test accuracy up to 1.5%

■ Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function

■ Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test

■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards

■ Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function


Technical parameters:

Applied standardIEC 60884-1
Applied clause11.5
AC withstand voltage
Output voltage setting rangeAC 200~5000V
Output voltage accuracy

±(1.5%×setting+5words)

Output voltage setting step

1V

Output frequency

50/60Hz

Output waveform

Sine wave
Distortion of output waveformLess than 2% (at purely resistive load)

Output waveform adjustment rate

Less than (2%* setting +5V)

Output capacity

500VA

Output voltage ramp-down time setting range

0~300s

Set step

0.1s

Breakdown current measurement range0.10~99.99mA

Breakdown current test accuracy

±(1.5%×reading+5words)

Breakdown current preset upper limit0.10~99.99mA
Breakdown current preset lower limit

0.00~5.00mA

Breakdown current preset step

0.01mA/step

Test time setting range

1~300s

Test time setting step

1s/step
Arc detection

1~9 Level (level 9 is the highest sensitivity)

Insulation resistance
Output voltage setting rangeDC 200~1000V
Output voltage accuracy± (1.5%×reading+5 words)
Output voltage setting step

1V

Output capacity60VA
Output voltage ramp-down time setting range0~300s

Set step

0.1s

Insulation resistance measurement range / accuracy

1~2000 MΩ ≤100 MΩ: ±(5%×displaying+3words) >100 MΩ: ±(8%×displaying+8words)
Insulation resistance alarm setting range

Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ

Test time range, resolution1~300s 1s/step
Ground resistance
Ground current output range / accuracy

AC 5.0~30.0A

Ground current accuracy

±(1.5%×setting+0.2A)

Ground resistance measurement range

10.0~600mΩ

Ground resistance measurement accuracy±(1.5%×displaying+3mΩ)
Ground resistance alarm setting rangeUpper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;lower limit:0.0~100mΩ

Ground resistance setting step

1mΩ

Test time range

1~300s

Test time step1s/step
Leakage current

The output voltage

1.06 times rated voltage provided by the built-in variable frequency power supply
Leak type setting

Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized

Output voltage measurement rangeAC 50~280V
Output voltage frequency

AC 45~65Hz

Output voltage accuracy±(0.5%×displaying+2words)
Leakage current measurement range

0.05~20.00mA

Leakage current measurement accuracy

± (1.5%× displaying +10uA)

Leakage current setting alarm range

Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA

Leakage current setting step

0.01mA

Test time range

1~300s 1s/step

Power

Output voltage

1.0 times rated voltage, provided by built-in variable frequency power supply

Output voltage measurement range / accuracy

AC 50~280V ±(0.5%×displaying+2 words)

Output current measurement range / accuracy

AC 0.20~30.00A ±(0.5%× displaying +2 words )

Active power measurement range / accuracy

30~6000W ±(0.5%× displaying +5 words )


Power setting alarm rangeUpper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W
Test time range / resolution1~300s 1s/step
Low voltage start
Output voltage0.85 times rated voltage provided by the built-in variable frequency power supply
Output voltage measurement range / accuracy

AC 50~280V ±(0.5%× displaying +2words)

Starting current measurement range / accuracy

AC 0.20~30.00A ±(0.5%× displaying +2 words )

Current setting alarm rangeUpper limit:0.20~30.00A Lower limit: 0.00~25.00A
Test time range

1~300s 1s/step

Communication

232 485 can Bu
Interfaces TCP / IP interface
External control method

PLC interface, switch signal

System appearance

Size:600W*1840H*600Dmm Height with pulley, alarm light
System standard accessoriesPower cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1