IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN6618
Minimum Order Quantity:1
Delivery Time:30 Days
Payment Terms:L/C, , T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

IEC 61000-4-6 and ISO 11452-4 Conducted RF Immunity Test System


System configuration:

Conducted RF immunity test system and BCI test

Lower test equipment wavelength (the EUT) than the size of the frequency (e.g., 80MHz or less) much less interference wave, in contrast, leads apparatus (including power lines and the overhead lines extend, a communication line interface length of cable, etc.) is an interference wave may reach several wavelengths or longer. Apparatus becomes the passive antenna lead, susceptible to interference from RF fields induced near field electromagnetic RF voltage and current ultimately affect device formation.


The bulk current injection (BCI) test method is based on current injection into the wiring harness using a current probe as a transformer where the harness forms the secondary winding.


Technical parameters:


Model and NameBasic parametersQuantity
Signal generatorFrequency range: 9 kHz ~ 1 GHz1
Power AmplifierFrequency range: 100kHz ~ 400MHz; Output Power: 100W1
CDN M2M2 ,32A CDN network and its calibration kit, attenuators,1
CDN M3M3,32A CDN network and its calibration kit, attenuators,1
RF Power MeterRF power meter: 9kHz-3GHz3
EM Injection Clamps

10kHz - 1GHz: 100 watts COUPLING APERTURE 23mm

Include: calibration fixture

1
Aadapter50/150 Ohm adapter2
50 Ohm50 Ohm closing1
ATT6 dB, 60 W damper1
Bulk Current Injection10 kHz - 400 MHz 100W inner diameter1
Calibration FixturesCalibration Fixtures for Bulk Current Injection1
CURRENT PROBE

Frequency: 10 kHz – 400 MHz

Internal diameter: 40 mm

1
Test softwareAutomatic calibration radiated immunity test software, compliance with IEC61000-4-6, ISO11452-41
System integrationSystems design, integration, project management, factory acceptance, site installation, commissioning and training1
Includingfollowing accessories for IEC 61000-4-6 measurements:

- M2+3 connection network

- EM clamp for connecting to an at least 20 mm diameter cable

- The calibration accessories of the EM clamp (calibration fixture)

- 50/150 Ohm adapter (2 pcs)

- 50 Ohm closing

- 6 dB, at least 60 W damper

- current measuring ring for the control measurement

- the necessary connecting RF cables for all the above mentioned.


Test Conducted RF immunity schematic


China IEC 61000-4-6 EMC Conducted RF Immunity And  BCI Test System supplier

IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System

Inquiry Cart 0