Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector


Product overview:


The protective mask dead space tester is used for the detection of the protective mask dead space, that is, the volume fraction of CO2 in the inhaled gas.


Equipment advantages:


1. The test process is completely controlled by a computer program, which realizes automatic detection, automatic recording, and automatic calculation of the change of the carbon dioxide concentration value of the inhaled gas during the entire test process. The operation is simple and easy to use.

2. There is no need to adjust the breathing frequency and the amount of breathing during the test. The breathing frequency and the amount of breathing can be changed by simple parameter setting operations on the computer. The adjustment is very convenient and accurate.

3. The one-way valve that controls the breathing channel is automatically controlled by the ventilator using a solenoid valve group, which is completely synchronized with the action of the ventilator, making the detection result more accurate.

4. All data of the test process is automatically saved in the computer, and a test report is automatically generated. The data of the entire process can be viewed through the computer at any time, and a report of the test results can be printed at any time.


Technical parameters:

NameSpecifications
Simulated breathing frequency10~40 times /min
Adjustable range of simulated tidal volume0.5~3.0L/min
Volume fraction of the carbon dioxide gas source5.0±0.1%
Range of carbon dioxide flowmeter≥ 40L/min
Range of carbon dioxide analyzer≥ 12%, accuracy ≥ 0.1%
Electric fanWind speed 0.5m/s
Breathing frequency20 times/ min
Breathing tidal volume1.5L
PowerAC220V 50Hz
Dimensions980mm*820mm*1400mm
China Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector supplier

Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector

Inquiry Cart 0