16KPa Pressure 2mL Synthetic Blood Penetration Tester Time Accuracy 0.1s

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN122606
Minimum Order Quantity:1
Delivery Time:30 Days
Payment Terms:T/T, L/C, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Medical Masks 16KPa Pressure 2mL Synthetic Blood Penetration Tester


Product overview:


The medical mask synthetic blood penetration tester is used to measure the jet penetration performance of liquid sources such as synthetic blood to evaluate mask’s safety protection performance. Mainly used to test the permeability of masks to blood, body fluids, blood pathogens (tested with Phi-X174 antibiotics), synthetic blood and other liquids. It is suitable for liquid penetration resistance of protective equipment such as masks, gloves, protective clothing, outer cover, coveralls, boots and other protective equipment. This equipment can output test report and save test data.


Test method:


The medical mask sample is supported on the test device, and 2mL of synthetic blood with a surface tension of 0.042 ± 0.002n / m is sprayed from a cannula with an inner diameter of 0.84mm at a distance of 300mm to the mask under test at a pressure of 16kpa in the horizontal direction. Simulate the scene of the mask being splashed by blood from the perforated blood vessel. Take off and visually check the penetration of synthetic blood on the other side of the mask within 10 seconds. Test the medical mask with the corresponding liquid jet pressure of 450cm / s, 550cm / s, 635cm / s, record the test result of each jet velocity, give out the highest blood pressure corresponding to the acceptable quality level limit of 4 for medical masks.


Technical parameters:


Basic test principleSimulate breathing through a vacuum pump, and carry out the pressure difference detection
Main parametersTest pressure0~16KPa
Micro-pressure measuring range0~0.1KPa
Pressure value resolution0.1kPa
Time accuracy0.1s
Test mediumSynthetic blood
Control methodManual
Blood volume2ml
Scope of applicationSurgical mask

China 16KPa Pressure 2mL Synthetic Blood Penetration Tester Time Accuracy 0.1s supplier

16KPa Pressure 2mL Synthetic Blood Penetration Tester Time Accuracy 0.1s

Inquiry Cart 0