Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11

Brand Name:Sinuo
Certification:Calibration Certificate(cost additional )
Model Number:SN2111
Minimum Order Quantity:1 Set
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

IEC 60884-1 Figure 11 Conductors Undue Damage Checking Test Apparatus


Standard: IEC60884-1 clause 12.2.5, figure 11.


Application: It is used to check terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).


Test sample: Plugs and socket-outlets terminals.


Technical Parameters:


ModelSN2111
Test rate10±2 RPM
Diameter of gyration75mm
Test times0~9999
Test weights0.3, 0.4, 0.7, 0.9, 1.4, 2kg
Test height260, 280, 300, 320mm
Diameter of bushing6.5, 9.5, 13, 14.5mm
Complied standardsIEC60884-1, IEC60669-1

Test processes:


The terminal is placed in the test apparatus according to figure 11 and fitted with rigid, solid, stranded and/or flexible conductor(s), according to table 3 first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to table 6.

Where rigid stranded conductors do not exist, the test may be made with rigid solid conductors only. In this case, there is no need for further tests.
The length of the test conductor shall be 75 mm longer than the height (H) specified in table 9.
The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in table 9. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.
The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in table 9. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.
A mass as specified in table 9 is suspended from the end of the conductor. The duration of the test is approximately 15 min.
During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.


Comparison table of the weight, height and bushing as below:

Nominal cross-sectional area of conductor ( mm²)

Diameter of bushing Hole

( mm)

Height (mm)Mass for conductor (kg)
0.56.52600.3
0.756.52600.4
1.06.52600.4
1.56.52600.4
2.59.52800.7
4.09.52800.9
6.09.52801.4
10.09.52802.0
16.013.03002.9
  1. The Corresponding size with mm² see IEC 60999-1.
  2. The height:±15mm.
  3. If the bushing-hole diameter is not large enough, you can choose the larger one.
  4. 2.9Kg weights are composed of 2Kg weights and 0.9Kg weights