Home /Other Measuring & Analysing Instruments /

20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels

20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SNBT4004FA-20V100A
Minimum Order Quantity:1
Delivery Time:1 Month
Payment Terms:T/T, L/C, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

20V 100A Automotive Battery Charge Discharge Capacity Independent 4 Channels Testing Equipment


Overview:

This battery charge discharge testing equipment meets the requirements of lithium ion battery or lead acid battery pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.

Technical Parameters:

Project index

Parameter index

Input PowerAC 380V±10%/50Hz (can be customized)
ResolutionAD:16bit;DA:16bit
Input Resistance≥1MΩ
Input Power11139W
Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
Channel Control ModeIndependent control
VoltageVoltage Range Per Channel100mV-20V
Minimum discharge voltage2.5V
Accuracy± 0.1% of FS
Stability± 0.1% of FS
CurrentCurrent Range Per Channel0.5 A~100A
Constant voltage cutoff current0.2A
Accuracy± 0.1% of FS
Stability± 0.1% of FS
PowerOutput Power Per Channel2000W
Stability± 0.2% of FS
TimeCurrent Response TimeTime of current rising to 100A is 20ms
Step Time Range1~365*24 hours, Time Form Support 00:00:00:000(h, min, s, ms)
Data RecordingRecord ConditionTime△t: 100ms
Voltage△U:40mV
Current△I: 200mA
Record Frequency10Hz
ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant current and constant voltage of the battery pack
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
Pulse ModeCharge modeConstant current mode, Constant power mode
Discharge modeConstant current mode, Constant power mode
Min. pulse width500ms
Number of pulseSingle pulse step supports 32 different pulses
Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
Cutoff conditionVoltage, relative time
DCIR TestSupports custom point retrieval for DCR calculations
CycleLoop Measure Range1~65535 times
Max Steps Per Loop254
Nested LoopWith nested loop function, max support 3 layers
ProtectionSoftware Protection
  • Power-down Data Protection
  • Off-line Testing Function
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time+, Single Cell Difference
  • With anti-reverse connection function
Voltage and current detection samplingFour-wire connection
Noise<85dB
DatabaseMySQL Database
A Means of Communication of Upper MachineTCP/IP Protocol
Data OutputEXCEL2003,2010, TXT
Communication InterfaceEthernet Port
Main Channels No. Per Unit4
Dimensions30U chamber, W*D*H:600*600*1520(mm)


Equipment Working Environment :

Project index

Parameter index

Working Temperature Range10℃ ~ 40℃1
Storage Temperature Range-10℃ ~ 50℃
Working Environment Relative Humidity Range≤70% RH (No condensation)
Storage Environment Relative Humidity Range≤80% RH (No condensation)
Auxiliary channel voltage range (optional and customized)-5V~5V

Auxiliary channel voltage accuracy
(optional and customized)

±0.1%ofFS

The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.


China 20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels supplier

20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels

Inquiry Cart 0