Add to Cart
IEC 60335-1 12.5kV 1.2/50μs or IEC60950-1 7kV 10/700μs Impulse
Voltages Generator
Standards & Clauses:
IEC60335-1:2016 “Household and similar electrical
appliances-Safety-Part1:General requirements” clause 14
IEC60950-1:2013 “Information technology
equipment-Safety-Part1:General requirements” clause1.5.7.2,
1.5.7.3,2.10.3.9,6.2.2.1,7.4.2,7.4.3,G5,Annexe N
IEC60065:2014 “Audio, video and similar electronic apparatus-Safety
requirements” clause13.3.4,Annex J.5, Annex K
IEC 61180-1:2016 “High-voltage test techniques for low voltage
equipment - Part 1: Definitions, test and procedure requirements,
test equipment” clause 7
Samples and Restrictions:
Household and similar appliances, information technology equipment,
audio and video electronic equipment.
Application:
It is used to verify that the appliances shall withstand the
transient over-voltages to which they may be subjected.
Test Principle:
The impulse voltage generator with a wave of 1.2/50us(10/700us is
optional) is a standard lightning wave test device. The front time
of the impulse voltage is 1.2us(10us), the time to half -value is
50us(700us). The impulse voltage test is a destructive test in
which a breakdown occurs if the test specimen cannot withstand the
applied voltage. When the sample breaks down, sparks and discharge
sounds will be generated. The peak voltage of the instrument will
drop significantly (close to zero) when it is no-load. When the
same voltage is applied again, the above phenomenon will occur.
Structure:
Equipment size: about 470 × 260 × 500 (mm) W × D × H
Equipment weight: 30kg
Use Environment:
Power supply:AC220V±10%/50-60Hz or match client's local power
supply requirements
Temperature: 15 ° C -35 ° C, relative humidity 10% -75%
Technical Parameters:
Model | SN1104 | SN1104-2 |
Open Circuit Output voltage | 12.5kV (Max) ±5% | 6kV (Max) ±5% |
Front Time | 1.2μs ±30% | 10μs ±30% |
Time to Half -value | 50μs ±20% | 700μs ±20% |
Output Polarity | Positive, negative, positive & negative cycling | Positive, negative, positive & negative cycling |
Output Impedance (optional) | 12Ω±10%,500Ωis optional | 40Ω±10% |
Trigger Mode | Automatic or manual, single trigger | Automatic or manual, single trigger |
Test Times | 1-9999 times | 1-9999 times |
Interval Time | 3-999s(3s of which is the charging time inherent in the device) | 3-999s (3s of which is the charging time inherent in the device) |
Measured Waveform |
|
|