Product description
Products meet GB17467-1998 "high and low voltage prefabricated substation" and IEC1330 standards. The voltage classes are applicable to 35KV and below, the small unattended substation, with main interior capacity of 2000KVA and below,
The prefabricated substation can complete the transformation, distribution, transmission, measurement, compensation of electrical energy, system control and protection as well as communication functions.
Box type substation is a compact complete set of distribution
equipment that combines high-voltage switchgear, distribution
transformer and low-voltage switchgear according to certain wiring
scheme. Main components: transformer, high-voltage switchgear and
its control equipment, low-voltage switchgear and its control
equipment, corresponding internal connecting wire (cable, busbar,
etc.) and other auxiliary equipment.
1. Small volume,compact structure,reliable power supply and easy
for installation;it can be realize single power supply,double power
supply,or ring net supply,with double-fuse protection,low running
cost.
2. The casing surface is treated by electrostatic painting and has
good wearing resistance.It is applicable to both ring network and
single/double power supply,is convenient for shifting,and can
enhance the reliability of power supply.
3. The transformer adopts environment-friendly S11 series spiral
core,non-excited voltage regulation,full-enclosed type,featuring
energy saving and low noise.The amorphous alloy transformer is also
available if required by clents.HV load switches and protective
fuse are placed in oil filled iron tank,and the tank is of
full-enclosed structure.
4. The LV room is provided with watt-hour meters,voltmeters,and
breakers of four outgoing lines,reactive power compensation can
also be provided if necessary.
5. It uses S11 series spiral core transformer,its idle loss is 30%-40% lower than S9,and
noise 7~10dB lower than S9.
6. The combination transformer is characterized by reliable power
supply,reasonable structure,quick installation,flexible and easy
operation,small volume,low construction cost,ect.
7. It is suitable for outdoor and indoor use,and is widely used in
industrial parks,residential quarters,business centers and high
risers.
· Use condition
1. The maximum ambient air temperature shall not exceed 45℃, and
the minimum shall not exceed - 45℃;
2. The altitude shall not exceed 1000m. If special customized
transformers and low-voltage components are used, the altitude can
reach 4000m;
3. It shall be placed in a place with a vertical inclination of no
more than 5°and no severe vibration or impact;
4. The air humidity is not more than 90% (+ 25℃);
5. Gas place without conducting dust, explosion hazard, corrosion
metal and electrical components;
6. Outdoor wind speed shall not exceed 35m/s.
7. If the above normal use environment conditions are exceeded, the
customer can customize it with our company.
Note: Due to continuous product improvement, the dimensions provided in
this sample are for reference only. If necessary, our company can
design and produce according to user requirements. Please contact
the company in time.
Configuration | Power capacity | W | H | D | W1 | D1 | D2 | H1 | Weight(kg) |
Standard π configuration | ≤125kVA | 2000 | 1580 | 1116 | 1180 | 508 | 575 | 1240 | 2000 |
160~500kVA | 2000 | 1580 | 1350 | 1330 | 508 | 655 | 1340 | 2950 | |
630kVA | 2000 | 1710 | 1560 | 1420 | 632 | 775 | 1480 | 3400 | |
800kVA | 2000 | 1710 | 1690 | 1420 | 632 | 775 | 1480 | 3600 | |
1000kVA | 2000 | 1710 | 1820 | 1420 | 632 | 815 | 1480 | 4000 | |
1250kVA | 2000 | 1710 | 1840 | 1560 | 632 | 795 | 1480 | 4800 | |
1600kVA | 2205 | 1710 | 1920 | 1680 | 632 | 920 | 1520 | 5700 | |
Extra π configuration | ≤125kVA | 1900 | 1900 | 1240 | 1180 | 632 | 575 | 1240 | 2200 |
160~500kVA | 1900 | 1900 | 1474 | 1330 | 632 | 655 | 1340 | 3150 | |
630kVA | 1900 | 1900 | 1560 | 1420 | 632 | 775 | 1480 | 3600 | |
800kVA | 1900 | 1900 | 1690 | 1420 | 632 | 775 | 1480 | 3800 | |
1000kVA | 1900 | 1900 | 1780 | 1420 | 632 | 815 | 1480 | 4200 |
· Ordering instruction
1. Conceptual drawing or electrical schematic diagram of main
circuit.
2. Model, specification and quantity of main components.
3. Incoming and outgoing line mode and cable specification, etc.
4. Shell material and appearance: composite plate, steel plate,
stainless steel plate, cement plate, etc.
5. Other order requirements.