200Kva oil immersed transformer 11kv 10kv to 415v 400v three phase transformer

Brand Name:HENGFENGYOU
Certification:ISO IEC CB COC KEMA SNI SABS CCC
Model Number:S11
Minimum Order Quantity:1
Delivery Time:15 DAYS
Payment Terms:LC T/T
Contact Now

Add to Cart

Verified Supplier
Location: Qingdao Shandong China
Address: N0.506 Huicheng Road, Chengyang District, Qingdao City,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Oil-immersed transformer S11,30-2500KVA,10KV series,3 phae/full sealed/double winding


Product Features:

Our company can produce a variety of oil-immersed transformers with a voltage rating of 35kV or less and a capacity of 12500kVA or less. The variety includes S9, S11 series and S13, S15 series of energy-saving products. The product is widely used in industrial and mining enterprises, agriculture, civil construction and other distribution sites as well as oil, chemical industry, more oil, more chemical substances in the places.


1. Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.


2. Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.


3. High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.


4. Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.



Technical parameters of S13 10kV oil-immersed transforme

Rated Capacity
(kVA)
TypeVector GroupNo-Load
loss (kW)
Load loss (kW)Short-circuit impedance
(%)
30S13-30/10Y,yn00.080.63/0.64
50S13-50/100.10.91/0.87
80S13-80/100.131.31/1.25
100S13-100/100.151.58/1.5
125S13-125/100.171.89/1.8
160S13-160/100.22.31/2.2
200S13-200/100.242.73/2.6
250S13-250/100.293.2/3.05
315S13-315/100.343.83/3.65
400S13-400/100.414.52/4.3
500S13-500/100.485.41/5.1
630S13-630/100.576.24.5
800S13-800/100.77.5
1000S13-1000/100.8310.3
1250S13-1250/100.9712
1600S13-1600/101.1714.5

Material
Oxygen-free copper lines of lower resistivity, which will become smoother and burr-free after series of additional surface treatment, so the load loss of our transformer is lower and the electric performance is better.
High-quality silicon-steel plates which are of lower unit loss, and the no-load of the transformers is lower.
High-quality wooden laminating insulation pieces, which won’t split or move even under the influence of short circuit.
Thoroughly filtrated transformer oil containing less water, gas and impurities, which makes our transformers work better.
High-quality rubber sealing material, which can prevent the transformers form aging or leakage.


·Service conditions

1. The maximum ambient air temperature shall not exceed 40 ℃, and the minimum shall not below - 25 ℃;

2. The altitude shall not exceed 1000m. If special customized transformers and low-voltage components are used, the altitude can reach 4000m;

3. The vertical inclination is no more than 5 °, and no violent vibration and impact;

4. The air humidity is not more than 90% (+ 25 ℃);

5. No gas and conductive dust that will seriously affect the insulation of transformer, no explosion hazard and corrosion of electrical components;

6. Outdoor wind speed shall not exceed 35m / s.

7. If service conditions beyond the above, specially customized product is available.


Workshop



Grounding Transofrmer Application:


The grounding transformer is used to provide a path to an ungrounded system or when the system neutral is not available for some reason, for example, when a system is delta connected. It provides a low impedance path to the neutral and also limits the transient overvoltage when the ground faults occur in the system. The grounding of the system can be done in the following way


Delta-Star Grounding Transformer

In a case of delta-star grounding transformer, the delta side is closed to provide a path for zero-sequence current. The star winding must be of the same voltage rating as the circuit that is to be grounded, whereas the delta voltage rating can be chosen to be any standard voltage level.