W20-12 / 630-25KA outdoor high voltage vacuum circuit breaker
ZW20-12 series of Outdoor High voltage Current Communication boundary of vacuum circuit breaker was set at rated voltage of 12kV, 3-phase AC of 50Hz outdoor high voltage switchgear. It was mainly used at load current, overload current and short circuit current of cut-off, shut-off power system. It was also used at distribution network protect and control of substation, factories and towns & countries, especially applicable for frequent operate places and town automatic distribution network. It was made up of mature cabinet type hermetic structure, inner full of SF6, good sealing performance, not affected by outside and it was a product of maintenance-free. Its spring control mechanism used straight chain main transmission and trip coil system, high reliability, good circuit breaker.
Structural features
Town, country reform ideal equipment: It can be set with control
mechanism to remote control, remote measure and adjustment.
Flexible operation, convenient: This product has performance of
electric energy storage, electric close-open and hand energy
storage, hand close-open, it also can be operated close or far
remote.
Superior performance of open-shut: 30 times of open-shut short
current at 20kA.
Small capacity of operation and high reliability: New designed
small electric spring structure, parts numbers and operate
capacity(about 30W) can be reduced to *** level.
Maintenance-free performance: Main breaker circuit and bivariate
device, operate structure were all sealed in air of SF6(zero
pressure) and not affected by outside.
Reliable sealability: It was used of mature seal structure
technology and reliable capacity.
Special in-out line method: It was used silicon rubber pipe and
make terminals distance sufficient, good insulator outside.
Safety in use: There was explosion proof equipment set on the top
of box, even if breakdown inner, high temperature air or splash
will not out.
Order information
The customer needs provide main parameters of the transformer
(input and output voltage, capacity, loss, etc.)
Other customer requirements
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
No. | Item | Unit | Data |
1 | Rated voltage | kV | 12 |
2 | Rated frequency | Hz | 50 |
3 | Rated current | A | 630,1250 |
4 | Rated short circuit breaking current | kA | 12.5,16,20,25 |
5 | Rated peak withstand current | kA | 31.5,40,50,63 |
6 | Rated short time tolerance current(4s) | kA | 12.5,16,20,25 |
7 | Rated short circuit opening and closing current | kA | 31.5,40,50,63 |
8 | Institution life | time | 10000 |
9 | Rated short open circuit current switch frequency | time | 30 |
10 | Rated current open circuit frequency | time | 10000 |
11 | Power frequency withstand voltage (1min) : phase, ground/fracture | kV | 42/48 |
12 | Lightning shock withstand pressure(peak)phase, ground/fracture | kV | 75/85 |
13 | Power frequency withstand voltage of the secondary circuit )(1min) | kV | 2 |
14 | Net weight | kg | 140 |
·Order instructions:
1. The customer needs provide main parameters of the transformer (input and output voltage, capacity, loss, etc.)
2. Other customer requirements
Package Details: