Add to Cart
Low Voltage Industrial Electrical Switchgear Spray Paint Surface Treatment
General:
GGD AC LV fixed type switchgear is applicable to the distribution
system with AC 50Hz,rated working voltage 380V,rated current to
3150A below in power station,substation,plant enterprise etc.,used
for power transfer,distribution and control for power,lighting and
distribution devices.The product has characteristics of high
breaking capacity,fine dynamic and thermal stability,flexible
electric project,convenient combination,better serial
practicability,novel structure and high protection grade etc.It
accords with the standards IEC439 Low voltage complete switch
device and control device and GB7251.1 Low voltage complete switch
device etc.
Characteristics:
The body of GGD AC LV fixed type switchgear adopts universal
cabinet type. Framework is assembled with 8MF cold bending bar
steel through part welding. Framework components and special mating
elements are matched by bar steel pointed manufactory for ensuring
the precision and quality of cabinet. Components of universal
cabinet is designed according to module principle, and with 20
moduls mounting hole and high universal coefficient.
Completely in view of the heat rejection during cabinet running.
Heat rejectionsl ots of different quantities are installed in upper
and underside both ends of cabinet.
According to the requirements on mold design for modern industry
products, adopting the method of golden mean ratio to design
cabinet outline and parting dimensions of each part, to make the
whole cabinet beautiful and decent.
Cabinet gate is connected with framework with rotation axis type
movable hinge. With convenient installation and disassembly. One
mount type rubber strip is set in
edge fold of gate. Filler rod between gate and framework has
certain compression stroke when closing the gate. It can prevent
gate from impacting cabinet directly and
also advance the protection grade for gate.
Connect the meter gate set with electrical components with
framework by multistrand soft copper wire. Connect the mounting
pieces inside the cabinet with framework by knurled screws. The
whole cabinet constructs complete earthing protective circuit.
Top cover of cabinet can be disassembled if necessary for
convenience to the assembly and adjustment for main bus bar at
site. Four squares of cabinet are set
with slinger for hoisting and shipping.
Protection grade of cabinet: IP30. User can choose within IP20~IP40
according to environmental requirements.
Conditions for normal operating environment:
1. Ambient air temperature: -5~+40 and the average temperature
should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation
site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40.
Higher relative humidity is allowed at lower temperature. Ex. 90%
at +20. But in view of the temperature change, it is possible that
moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the
sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.
Main technical parameters:
Type | Rated voltage(V) | Rated current(A) | Rated short circuitbreaking current(kA) | Rated short timewithstand current(kA) | Rated peakwithstand current(kA) |
GGD1 | 380 | 1000 600(630) 400 | 15 | 15(1S) | 30 |
GGD2 | 380 | 1500 1600 1000 | 30 | 30(1S) | 63 |
GGD3 | 380 | 3150 (2500) 2000 | 50 | 50(1S) | 105 |