ALEPH OD22 24VDC 30mA Request To Exit Detector Passive Infrared

Brand Name:ALEPH
Certification:CE ISO
Model Number:OD-22
Minimum Order Quantity:1pcs
Delivery Time:25-30 days
Payment Terms:TT IN ADVANCE
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong China
Address: No. 301A, 3F, C6 Bldg, Hengfeng,No 739 Zhoushi Rd,Hezhou, Hangcheng, Bao'an, Shenzhen City, 518000 China
Supplier`s last login times: within 11 hours
Product Details Company Profile
Product Details

REQUEST-TO-EXIT Red LED Passive Infrared Sensor Available in white or brown enclosure


DESCRIPTION
The product has been given as the following : ALEPH High Performance Request‑to‑exit Detector.
Aleph OD22 FEATURES
Door monitor with sounder alert
Internal vertical pointability
• High sensitivity
1. SPECIFICATIONS
Supply Voltage12-24VDC or VAC .
Supply Current18-30mA@12-24VDC,45-80mA@12-24VAC
Relay Output2C Contact(N.C/N.O) , 24VDC 1A Max.
Detection TypePassive infrared
Relay Hold Time0.5-64 seconds
LED IndicationRed
RangeCoverage 12x5 ft at 7ft high,30x12 ft at 15 ft high(Adjustment )
Operating Temperature- 14°F to 131°F(- 10° C to 55°C)
Weight0. 4lb( 0. 18kg)
Humidity0-95% non-condensing
Dimensions6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm)

2. DIMENSIONS
3. DESCRIPTION AND OPERATION
4. DETECTION PATTERN


5. INSTALLATION
Mounting Procedure
1. Select a mounting location over the center of the door or doors to be covered. The target must walk
directly toward the detector.Mount the detector on the ceiling,wall,or door frame.
2. Remove the front cover from the detector.
3. Route the wiring as necessary through the wiring entrance(refer to the item 3 description and oper- ation).For surface wiring,use the break out wiring entrance on the front cover(at the same end as the wire entrance).
4. Loosely mount the back cover to the mounting sur- face using the supplied mounting screws.
5. Aim the detector for the desired coverage.
6. Mount the front cover on the detector.
Long Range/Short Range Adjustment
The OD-22 can be set to detect individuals at either a long rang(several steps from the door) or at short range (immediately in front of the door).If the build- ing includes a lengthy approach to the exit doorway and no other foot traffic in the area, choose the long range setting.
Setup and Testing
1. Apply power to the unit.
2. Wait at least 3 min for the detector to settle.
3. Test the unit by walking directly throgh the coverage area,to- ward the door.
4. Aim the detector up or down if necessary to obtain the proper coverage.
5. Check that the relay latch time is sufficient Adjust if necessary.
6. After confirming proper operation,replace the cover and walk test one more time to ensure the coverage has not changed.

China ALEPH OD22 24VDC 30mA Request To Exit Detector Passive Infrared supplier