Product Details

125kV Rotating anode X‐Ray tube assembly for CR or DR machine Equivalent To: Toshiba E7239


Stator key values

1-phase stator


Test pointC-MC-A
Winding resistance≈18.0…22.0Ω≈45.0…55.0Ω
Max.permissible operating voltage(run-up)230V±10%
Recommend operating voltage(run-up)160V±10%
Braking voltage70VDC
Run-on voltage in exposure80Vrms
Run-on voltage in fluoroscopy20V-40Vrms
Run-up time(depending on starter system)1.2s

Quick Detail:


◆ X-ray tube assembly for all routine diagnostic examinations with conventional or digital radiographic and fluoroscopic workstations

◆ The insert features: 16° Rhenium-Tungsten molybdenum target (RTM)
◆ Focal spots: Small 1.0, Large: 2.0
◆ Maximum tube voltage: 125kV
◆ Accommodated with IEC60526 type high-voltage cable receptacles
◆ High voltage generator should accord with IEC60601-2-7
◆ IEC Classification (IEC 60601-1:2005): Class I ME EQUIPMENT

◆ Equivalent To: Toshiba E7239



Description

.

● The designation is composed as follows:

SRMWHX7010TubeAHigh voltage socket with 90 degree direction
SRMWTX70-1.0/2.0-125BHigh voltage socket with 270 degree direction

Technical Data


PropertySpecificationStandard
Nominal input power(s) of the anodeF 1F 2IEC 60613
21kW(50/60Hz)42.5kW(50/60Hz)
Anode heat storage capacity100 kJ ( 140kHU)IEC 60613
Maximum cooling capacity of the anode475W
Heat storage capacity900kJ
Max. continuous heat dissipation without Air-circular180W

Anode material

Anode top coating material

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

Target angle (Ref: reference axis)16 °IEC 60788
X-ray tube assembly inherent filtration1.5 mm Al / 75kVIEC 60601-1-3
Focal spot nominal value(s)F1(small focus)F2(large focus)IEC 60336
1.02.0

X-ray tube nominal voltage

Radiographic

Fluoroscopic


125kV

100kV

IEC 60613

Data on cathode heating


Max. current

Max voltage

≈ /AC, < 20 kHz
F1F 2

5.1A

≈5.8~7.8V

5.1 A

≈7.7~10.4 V

Leakage radiation at 150 kV / 3mA in 1m distance≤ 1.0mGy/hIEC60601-1-3
Maximum radiation field573×573mm at SID 1m
X-ray tube assembly weightApprox. 18 kg

Conditions for operation,storage and transport


LimitsOperation LimitsTransport and Storage Limits
Ambient temperatureFrom 10℃to 40℃From- 20℃to 70℃
Relative humidity≤75%≤93%
Barometric pressureFrom 70kPa to 106kPaFrom 70kPa to 106kPa

More Detailed Images


More product:

TypeFocal spotmax.rating(KW)Max voltag(kV)Target angle()Target materialRotation rate(W/min)Max component heat content(KJ)Max anode heat content(KHU)Max anode continuous heat dissipation(W)
SRMWHX64100.3/0.65/17(50Hz)13010RTM2800900210300
SRMWHX64110.6/1.311/32(50Hz)13015RTM2800900110300
SRMWHX64120.8/1.812/33(50Hz)13015RTM280090070175
SRMWHX64600.6/1.311/33(50Hz)13015RTM2800/8400900110300
20/54(150Hz)
SRMWHX70101.0/2.021/42.5(50Hz)12516RTM2800900140475
SRMWHX71100.6/1.220/40(50Hz12512.5RTM2800900150500
SRMWHX72101.0/2.020/40(50Hz)12516TM2800900140410
SRMWHX72201.0/2.020/40(50Hz)15016TM2800900140410
SRMWHX73600.6/1.220/50(50Hz)15012RTM2800/8400900300750
30/74(150Hz)
SRMWHX74200.6/1.220/46(50Hz)15012RTM2800900150475
SRMWHX75200.6/1.220/50(50Hz)15012RTM2800900220750
SRMWHX76200.6/1.220/50(50Hz)15012RTM2800900300870
SRMWHX78100.6/1.518/47.5(50Hz)12514RTM2800900200410
SRMWHX90200.6/1.219/50(50Hz)15012RTM28001100300500
SRMWHX91201.0/2.030/50(50Hz)15016RTM28001100200490