Double Power 125A ATS Automatic Changeover Switch CB Level

Brand Name:Fenigal/OEM
Certification:CE,CCC
Model Number:ATS AC CB Class
Minimum Order Quantity:1 unit
Delivery Time:5-8 working days bulk order negotiate
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi Jiangsu China
Address: 606#, Building-B, 100 Dicui Road, Binhu District, Wuxi, Jiangsu, China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

FENIGAL Manufacturer & OEM of ATS products

FMQ2 CB level (motor type) double power automatic transfer switch

Structure features:

Control device: LCD controller

Product structure: small size, high current, simple structure, ATS-body

Features: fast switching speed, low failure rate, easy maintenance, reliable performance (with automatic switching time adjustable, ls ~ 99s) Wiring method: wiring before the board

Switching mode: grid to grid, grid to generator, self-injection self-repeating, self-injection non-self-repeating, mutual standby

Product shell frame: 63, 100, 225, 400, 630, 800, 1250, 1600

Product current: 20, 32, 40, 63, 80, 100, 125, 160, 200, 225, 250, 315, 400, 500

630, 800, 1000, 1250, 1600A

Product classification: Circuit breaker (CML TM30)

Number of product poles: 3, 4

ATS level: CB level with overload and short circuit protection


Technical requirements

♦In the automatic gear, when the common power under voltage, over voltage, loss of voltage switch to standby power; when the same fault occurs in the standby power, switch to double points position, the display shows automatic alarm at the same time


♦LCD screen protects 30s, display screen when button is pressed for the first time, the second time can enter the setting, enter the setting need password input.


♦When the manual setting is messy (dead), there is a reset key to reset to the barking value.


♦When the controller is set in automatic and manual position, the display shows double points when pressing the double points button on the controller panel, but no alarm.


When the controller is set to delay switching time, when the power failure is restored to normal within the set value, the double power supply will not be switched, and vice versa.


FMQ2-100/4P-Dl (basic type)

FMQ2-100/4P-D2 (intelligent type)

Use categoryAC-33iB
Rated working voltage UeAC400VAC380V
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV6kV6kV6kV6kV8kV8kV
Rated short-circuit breaking capacity Icn10kAlOkA20kA30kA30kA30kA30kA
Rated short-circuit turn-on capacity Icm17kA17kA40kA63kA63kA63kA63kA
Service life (times)Mechanical4500500030002000200025002500
Electrical15001000100010001000500500
Number of poles3,4
Operation cycle (sec/time)30S60S
Switching time0-99S

① Main terminal of common power inlet② Main terminal of backup power inlet
③ Main terminal of load side④ Signage⑤ Commonly used power break indicator
⑥Handle jack⑦ Plug sealing plate pulling button⑧ User external signal terminal
9 Controller signal connection terminal Imitation LCD display
11 Restore factory default key '1>setting key
⑬Displacement key 14Numeric plus key 15Numeric minus key
16Manual key⑰ Auto Key 18 Double split key
19 Common power fuse 20Standby power fuse diy 21Generator signal port and
Fire connection port

China Double Power 125A ATS Automatic Changeover Switch CB Level supplier

Double Power 125A ATS Automatic Changeover Switch CB Level