GCS/GCK/MNS/GGD Low Voltage Drawer Type Panel Board Switch Gear for Electrical Distribution IEC 60439
GCS switch cabinets/Switchgear panel
GCS device is suitable for power plants, petroleum, chemical, metallurgy, textile, high-rise building and other industries of power distribution system . In large power plant ,petrochemical system, and computer interface places with a high degree of automation,requiring for computer interface ,as the three-phase AC frequency of 50 (60) Hz, rated working voltage is 380V (400V), (660 V), rated current is 4000A and below, distribution in the power supply system, motor centralized control,power distribution using reactive power compensation of low voltage device.
Technical data
Item | Name | Parameter | |
1 | Main circuit rated voltage(V) | AC 380(400),(660) | |
2 | Rated voltage of auxiliary circuit(V) | AC 220,380(400) DC 110,220 | |
3 | Rated frequency(Hz) | 50/60 | |
4 | Rated insulation voltage(V) | 660(1000) | |
5 | Rated current(A) | Horizontal busbar | ≤4000 |
Vertical busbar(MCC) | 1000 | ||
6 | Busbar rated short-time withstand current(kA/1s) | 50,80 | |
7 | Busbar rated peak withstand current(kA/0.1s) | 105,176 | |
8 | Power frequency test voltage(V/1min) | Main circuit | 2500 |
Auxiliary circuit | 1760 | ||
9 | A bus or bus bar | Three-phase four wire system | A.B.C.PEN |
Three-phase five wire system | A.B.C.PE.N | ||
10 | Protection level | IP30.IP40 |
GCK switch cabinets/Switchgear panel
GCK switch cabinets/Switchgear panel apply to the exchange of 50HZ, rated insulation voltage 380V low-voltage distribution system as affected by electricity, feed, the mother Union, lighting, motor control and power compensation purposes, which includes Power Center (PC) and the Motor Control Center (MCC) the function and can be designed as a fixed cabinets and drawer cabinets hybrid systems to meet the needs of the different power supply.
GCK Switchgear panel for the whole assembly-type composite structure, the basic
framework with specific profiles, assembly formed.
2. Enclosure skeleton, part dimensions and hole size according to
the basic module, E = 20mm change.
3. In the MCC program, Switchgear panel parts into five areas (rooms): the level of bus zone, vertical
busbar area, functional unit area, cable rooms, neutral grounding
bus zone. District of mutual isolation, to ensure normal operation
of line, effectively preventing the failure to expand.
4. Since all structures Shelves are sturdy self-tapping locking
screw connection is made to avoid the welding deformation and
stress, improve accuracy and grounding continuity.
5. Good versatility, adaptability, a high degree of
standardization.
6. Functional unit (drawer) is out, insert as a lever action, 320mm
Following a single drawing board, 400mm above the upper and lower
pairs of pull pull, rack configuration roll
Dynamic bearing operating light and reliable.
7. MCC drawer has eight kinds of standard sizes, namely:
8. PC program, each one to three cabinets can be mounted air
circuit breaker.
9. MCC program in the second couplings, in the docking mode of use
of mobile rail-oriented, to ensure interchangeability of modules,
while the functional units can be used in accordance
10.This Switchgear panel is out type switch cabinet and other comparative features of
compact structure, high strength, high-performance, safe and
reliable and so on.
11.Framework, doors and so on with epoxy powder coating
electrostatic spray insulation is good, durabletion
Type | Switchgear panel Project | Switchgear panel Specifications | ||
GCK | Switchgear panel Standard | GB7251,IEC439,VPE0660,JB/T9661 | ||
Switchgear panel Protection level | IP4X | |||
Rated working voltageV | 380 | |||
frequency HZ | 50 | |||
Rated insulation voltage | 660 | |||
Switchgear panel Working environment | environment | |||
Altitude | ≤2000m | |||
Temperature | -10~40, -30 -10 ~ +40 in storage, transport conditions, | |||
Relative Humidity | ≤90% | |||
Control of motor capacity KW | 0.45~155 | |||
Switchgear panel Mechanical life | 500 | |||
Switchgear panel Rated current | 1600,2000,2500,3200,4000 | |||
1000,1200 | ||||
Main circuit contact connector | 200,400,630 | |||
Auxiliary circuit contact connector | 10,20 | |||
The maximum current-fed circuit | PC | 1600 | ||
MCC | 630 | |||
the electric circuit | 1000,1600,2000,2500,3150,4000 | |||
Rated short-time withstand current | RMS | 50,80 | ||
peak | 105,176 | |||
Pressure V/1min | 2500 |
MNS Drawer Type Low-voltage Switchboard
MNS system are suitable for applications in all fields concerning
the generation, distribution and use of electrical energy, e. g.,
they can be used as: Main and sub-distribution boards for energy
and Motor current supply of Motor Control Centers
• Utility companies
• Power plants
• Oil refineries
• Off-shore drilling platforms
• Production facilities
• Buildings for other than dwelling purposes.
The MNS system is full complied with GB7251.1, IEC 439-1, EN 60
439-1, VDE 0660 part 500, BS 5486 Part 1 and UTE 63-410
Main technical data
No. | Item | Unit | data | ||
1 | Rated voltage | V | Up to 690 | ||
2 | Rated current for system | A | 4000(special to 6300A) | ||
3 | Rated current for busbar | Horizontal Busbar | A | Busbar 6300 *extremely* | |
1600 @+40ºC | |||||
Vertical Busbar | |||||
4 | Rated frequency | HZ | 2000*Note* | ||
5 | Power frequency with voltage 1min | kV | 8 | ||
6 | Rated Short-timeWithstand Current | Horizontal Busbar | kA/1S | 55-100/105-250 | |
60/130-150 | |||||
Vertical Busbar | |||||
7 | Over voltage class | III | |||
8 | Pollution Degree | 3 | |||
9 | Protection Degree | IP30/IP40/IP54 | |||
10 | Outline Dimensions(H*W*D) | mm | 2200×600(800/1000)×600(800/1000) |
Note:
1. The current of vertical busbar is extremely up to
2000A@+35ºC,(+40ºC with cooler) .
2. Protection Degree of IP54 is taken into consideration for
special design if needed.
GGD Low-voltage Distribution Cabinet
Product Overview
1.1 GGD AC low-voltage power distribution equipment for dry plants,
power plants, industrial enterprises and other power users of AC
50HZ, rated working voltage of 380V rated current 3150A
distribution system, as power, lighting and power distribution
equipment, power conversion , distribution and control purposes.
1.2 GGD AC low-voltage distribution cabinet is based on the
requirements of the Department of Energy in charge of the higher
level, the majority of electricity users and design department, in
a safe, economical, station management, reliable design principles
of new low-voltage distribution cabinet. Products with high
breaking capacity, dynamic thermal stability, electrical program
flexible combination of convenience, family, practical strong.
Novel structure, high level of protection, can be used for the
upgrading of low-voltage switchgear products.
1.3 GGD AC low-voltage power distribution cabinets meet IEC439
"Low-voltage switchgear and control equipment", G B7251
"Low-voltage switch equipment" and other standards.
Technical Data
Type | Rated Voltage | Rated current (A) | Rated short circuit break current(KA) | Rated short time withstand current (1s) KA | Rated peak withstand current (1s)KA |
GGD1 | 380 V | A.1000 | 15 | 15 | 15 |
B.600(630) | |||||
C.400 | |||||
GGD2 | 380V | A.1500 (1600) | 30 | 30 | 63 |
B.1000 | |||||
C.600 | |||||
GGD3 | 380V | A.3150 | 50 | 50 | 105 |
B.2500 | |||||
C.2000 |