Home /

Coarse Prefilter Wire Mesh Filter Material

Coarse Prefilter Wire Mesh Filter Material

Certification:ISO 9001-2015
Minimum Order Quantity:1 pc
Delivery Time:5-8 working days
Payment Terms:T/T, L/C
Place of Origin:China
Price:negotiation
Contact Now

Add to Cart

Verified Supplier
Location: Hengshui Hebei China
Supplier`s last login times: within 32 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Coarse prefilter wire mesh filter material with stainless steel frame


1.General introduction of wire mesh demister


The wire mesh demister is designed to collect liquid particles contained in the vapour phase after boiling, vacuum evaporation or bubbling process.

Small droplets in the gas contact the wide surface of the filaments of the mesh pad mist eliminator, gradually grow into large liquid droplets and flow and drop by a special structure accelerating the coalescing of the liquid droplets. The mesh pad of the mist eliminator is highly porous, so the vapour gas passes through the mist eliminator without hindrance, leaving only pure gas.

The process is not a type of filtering as the hole size of the knit mesh is not specially related to the size of the liquid droplets. This mist elimination is caused by the collision and sudden change resulting from the flowing speed of the small liquid droplets, and the coalescing of the liquid drips and gravity cause their descent.

This is a process combing mechanical and physical phenomenon.


2. Design of Wire Mesh Demister.


2.1General

A.Size, style, thickness, configuration, and materials are specified in XXX Project Specification – Vessels.

B.Mist Eliminator styles are defined as follows:

C.Style G is a mesh blanket having a variable knitted density. The vapor inlet section is the least dense and the outlet section the densest. Typical inlet/outlet knitted mesh densities are 5 lb/ft3 (80.1) and 9 lb/ft3 (144.2). The customer can require variable density blankets having slightly different knitted densities and wire diameters.

Style V is to be determined by the vendor, based on the process conditions provided by customer. Vendor may determine the mist eliminator type best suited to meet the mist elimination requirement. The selected style may include a mesh pad, vane or a combination of mesh & vanes. The mist eliminator may be oriented vertically, horizontally or at an angle determined by the vendor. A single pad of variable knitted density may also be applied.

2.2Construction

A.Mist Eliminators shall be fabricated in one piece or in the minimum number of sections required for insertion through the vessel manway.

B.Mesh pads shall fit tightly into the pad containment system.

C.Mesh pad layers shall not be more than 9 inches (230 mm) thick. Where more than one layer is required, joints shall be staggered.

D.One-piece circular mesh pads may be spiral in form.

2.3Supports and Grids

A.The general arrangement of Mist Eliminator supports and grids shall be as factory habit unless required by customer.

B.Final details of Mist Eliminator supports and hold down grids can also be furnished by the Mist Eliminator supplier.

C.The Mist Eliminator supplier shall furnish details of components attached to the vessel to the vessel fabricator in time to permit installation without altering the vessel fabrication schedule.

D.Each section of the mesh pad shall include a grid on each side.

E.Style G mesh pads shall be furnished with an inlet and an outlet rigid welded grid. The outlet grid and blanket outlet zone of the Style G mesh pad shall be distinctly marked “Outlet”.

F.Spiral mesh pads shall include X-type grids on both sides.

2.4Fastening Devices

As the Mist Eliminator fabricator we can supply wire ties or other devices to fasten the Mist Eliminator sections to the supports, attach the grids to their vessel supports, and where multiple layer Mist Eliminators are necessary, to secure the layers together.


3. Main types of wire mesh demister


Mesh

Density

Eq to: YORKDescription
80931For a given load of mist, the highest flow velocity is achieved of all styles. Ideal where it is required to minimize the pressure loss, possible clogging is concerned, the size of particle to be collected is relatively large, and/or a very high efficiency is not required.
144431Used for general purposes. An efficiency of 98 to 99% is achieved at a velocity of 1 to 5 m/sec.
192421Used where an especially high efficiency is required. While a pressure loss is slightly higher, it achieves an efficiency of 99 to 100% with particle sizes 3μ or more at a velocity of 1 to 6 m/sec., and is ideal where an efficiency of 90% or more is required at a velocity of 1 m/sec. or less.
216Used for collecting fine particles of 1 to 3μ in size.
Especially for a low-density mist of 1.0 g or less, it is used in a thickness of 200 to 300 mm.
432333Used for collecting fine particles. An efficiency higher than that of 216 can be achieved. The most remarkable characteristic is that it provides a high efficiency with a reduced thickness.

Wire Mesh Demister Package:

China Coarse Prefilter Wire Mesh Filter Material supplier

Coarse Prefilter Wire Mesh Filter Material

Inquiry Cart 0