True Double Version 3 Phase 20Kw 30Kw 60Kw G Tech UPS For Computer Room And Data Storage

Brand Name:Gtech
Certification:CE/ROHS
Model Number:PT
Minimum Order Quantity:5 PCS
Delivery Time:Sample: 7 days; Qty order: 20 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 1003 Yuemeite Building No.1 Gaoxin South 7th Road, High tech Industrial Park, Yuehai Street, Nanshan District, Shenzhen
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

Description:


Gtech 3-phase UPS is the most efficient way to deliver power to the load levels typically higher than 10KW such as data centers or industrial applications. This online Double Conversion delivers the highest level of power quality and is typically used to protect critical loads, which allows the inverter to generate excellent output power, free of any voltage and frequency fluctuations on the main power supply.


Batteries are connected (lead acid or lithium batteries) to the system and provide the reliable power back-up when AC input fails with zero transfer time. When AC input power is on, the UPS rectifier resumes carrying the load and begins charging the batteries, then power supply is delivered by the batteries through the inverter. This topology optimizes UPS efficiency and this 3 phase UPS is widely used for data centers, computer rooms, telecommunications and transportation applications


What's Special:


• True double-conversion
• DSP technology guarantees high performance
• Output power factor 1 and active power factor correction
• 50Hz/60Hz frequency converter mode
• ECO energy saving mode and EPO(Emergency power off) function
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized battery performance
• Adjustable battery numbers for long-run model
• Maintenance bypass available
• Parallel operation available
• Optional isolation transformer(noise rejection mode)
• Power walk-in function


Specifications:


MODEL10K (L)*15K(L)20K (L)*30K (L)*40K (L)60KL80KL
PHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph out3-phase in / 3-phase out
CAPACITY10KVA /10KW15KVA /15KW20KVA /20KW30KVA /30KW40KV /40KW60KVA /60KW80KVA /80KW
PARALLEL CAPABILITYup to 4 units in parallelup to 6 units in parallel
INPUT
Nominal Voltage3X400Vac (3Ph+N) /230Vac(1Ph+N)3 x 380/400/415 VAC (3Ph+N)
Voltage Range110-300 VAC @ 50% load
176-276 VAC @ 100% load
-30% ~ +20%
Frequency Range46~54 Hz or 56~64Hz40~70 Hz
Power Factor≧ 0.99 @ 100% Load
Harmonic Distortion (THDi)< 4% at full linear load
OUTPUT
Output Voltage3X380/400/415Vac (3Ph+N) or 208/220/230/240 VAC (1Ph+N)3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz50/60 Hz ± 1%
Current Crest Ratio3:1 (max.)
Harmonic Distortion≦ 2% THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer
Time
AC Mode to Batt. ModeZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sine wave
Overload
Capability
AC Mode100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
Battery Mode100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
BYPASS
Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
Voltage Range-30% ~ +20% (Adjustable)
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Overload Capability> 130% 1 minute (default) ; continuously working until breaker protection (optional)
EFFICIENCY
AC Mode95.5%96.0%
ECO Mode98.5%99.0%
Battery Mode94.5%96.0%
BATTERY
Standard
Model
Battery Type12V Lead Acid12V Lead Acid12 V/7 Ah12 V/9 AhN/A
Numbers(10+10) PCS(16+16) PCS(16+16) pcs x 2 strings
Typical Recharge Time4 hours recover to 90% capacity9 hours recover to 90% capacity
Charging Current (max.)2A (Adjustable)1A ~ 12A1A ~ 16 A (Adjustable)
Charging Voltage+/-13.65V*N (N = 10)+/-13.65V*N (N = 16~20)+/-218 VDC ± 10%
Long-run
Model
Battery TypeDepending on the applications
Numbers20PCS32PCS+/-16 pcs ~ +/- 20 pcs (Adjustable)
Charging Current (max.)1A/2A/3A/4A/5A/6A/7A/8A/9A/10A/11A/12A (Adjustable)12A maximum1A ~ 12A (Adjustable)1A~16 A (Adjustable)2A~24 A (Adjustable)2A~32A(Adjustable)
Charging Voltage+/-136.5VDC±10%+/-13.65V x N (N=16~20)
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Standard
Model
Dimension,DxWxH (mm)630 x 250 x 826815 x 300 x 1000N/A
Net Weight (kgs)103139225250
Long-run
Model
Dimension,DxWxH (mm)630 x 250 x 826815 x 300 x 1000790 x 360 x 1010
Net Weight (kgs)36436067108113
ENVIRONMENT
Operation Temperature0-40°C
Operation Humidity< 95% and non-condensing
Altitude**0 ~ 1500m at full load
Noise LevelLess than 60 dB@1 MeterLess than 65 dB @1 MeterLess than 63 dB @1 MeterLess than 65 dB @1 Meter
MANAGEMENT
Smart RS-232 / USBSupports Windows® Family, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser