Underground Power Armoured Electrical Cable HT 3 Phase Distribution Copper

Brand Name:HOLD-ONE
Certification:KEMA/CE/TUV/ISO/CE
Minimum Order Quantity:500M
Delivery Time:7 Days
Payment Terms:L/C, T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: East of Ping'an Avenue, Jiaoxi Town, Jiaozhou City, Shandong Province
Supplier`s last login times: within 24 hours
Product Details Company Profile
Product Details

Armoured Electrical Cable HT 3 Phase Distribution Copper Cable Underground Power Cable


Construction


Cu/XLPE/STA/PVC Armoured Electrical Cable


- Round bare aluminum core stranded according to IEC 60228
- Inner semi-conductive layer
- Core insulation XLPE
- Color code according to HD 308 S2
- Outer semi-conductive layer
- Semi-conductive tape
- Copper tape screen
- Filler
- PVC inner sheath
- Galvanized steel tape armour (STA)


Application

Used for power transmission and distribution line with voltage rated at 35kV and below.
High and Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.


MV(11kv 15kv 33kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kVNo.of CoreConductor cross-section area(mm2)
xlpe insulation1 core 3 core10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core
YJV, N2XSY;PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable
Al Core
YJLV, NA2XSY; PVC sheathed power cable
YJLV22;steel tape armoured,PVC sheathed power cable
YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable

Standard

International: IEC 60502, IEC 60228
China: GB/T 12706
Other standards such as BS, DIN and ICEA upon request


Technical data:

Maximum Conductor Temperature: under normal (90 OC), emergency (130OC) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 15 x cable O.D for single core
12 x cable O.D for multi core

Test voltage6 / 10 kV[kV]21 / 5 min.
12 / 20 kV[kV]42 / 5 min.
18 / 30 kV[kV]63 / 5 min.
Temperature rangein motion-5°C till +70°C
fixed-20°C till +70°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusmin.x diameter15
FlammabilitystandardEN 60332-1-2