PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

Brand Name:CNLN
Certification:CE/ISO
Model Number:Safety valve
Minimum Order Quantity:1 pcs
Delivery Time:5-8 work days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Chengdu Sichuan China
Address: No.789,Baiyun Road,East Industrial Park,Xindu District,Chengdu City,Sichuan Province P.C. 610500
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

Fall Lift Safety Valve Description

Product specifications

Product type: Spring direct acting full open

Nominal pressure: 2.5MPa,4.0MPa

Applicable medium: LO2, LN2, LAr, LNG, LC2H4, etc.

Applicable temperature: -196 ~ + 80 ℃

Connection: Thread


Material of main parts

Body and seat: stainless steel

Spring: stainless steel


Disc Seal: Reinforced


Customer Notice


1. If customers have special requirements for products, they must provide the following instructions in the order contract:
a. Structure length
b. Connection Type;
c. Nominal diameter
d. Product use medium and temperature and pressure range;
e. Testing, inspection standards and other requirements.

2. The factory can configure various driving devices according to customer specific requirements.


3. If the determined valve type and model are provided by the customer, the customer should correctly explain the meaning and requirements of its model, and sign the contract on the condition that the supply and demand sides understand and agree.

4. For futures and ordering customers, please call the letter to tell the valve model, specifications, quantity, delivery time and place in detail. And advance payment of 30% of the total contract amount, the supplier is ready for production.


Valve Type:safety valve

Connection Type: screw/thread

Nominal Diameter:DN15~25mm

Nominal Pressure:PN4.0MPa

Set Pressure:0.92MPa,1.76 MPa,2.42 MPa

Material: Valve Body:CF8;
Valve Disc:06Cr19Ni10;

Valve Seat:05Cr19Ni10;

Seal material:PTFE;

Suitable Medium:O2,N2,Ar,LNG,LCO2,etc

Suitable Temparature:(-80℃~+120℃)

Design and Manufacture:Conform to GB/T24925-2010

Testing:Conform to GB/T13927-2008

Valve Lifetime:Specified according to usage frequency

and installation location

Lead Time:Customized valves are usually 30~45 days; Stock valves are usually within 5 days.


Notes Of Fall Lift Safety Valve


1 . It should ensure that the pipe is blown clean before installation.


2 . When installing, make sure that the flow direction indicated by the arrow on the valve body should be consistent with the flow direction of the fluid.


3 . This valve has been degreased. Store and keep clean when installing.


4 . After the pipeline construction is completed, all the valves on the pipeline should be opened, and the residue in the pipeline should be thoroughly and thoroughly kept to ensure that the pipeline system is clean and free of debris.


5 . The installation system diagram with the oil-free requirements should be degreased.


6 . Slowly open and close during use.


7 . If the precision parts such as the valve disc, valve seat and valve stem are worn or damaged, it must be repaired and replaced in time.


8 . For parts such as gaskets and sealing materials, replace them with new ones each time.

Fall Lift Safety Valve Display


Fall Lift Safety Valve Specification


Product Code

Size

H

H1

L

M1

M2

D0

D1

D2

C158DJ15

179

62

47

M45×2

M36×2

36

15

32

C158DJ25

159

51

46

M30×1.5

M30×1.5

22

12

26

FAQ


Q. Are there any special requirements for OEM purchases?
A. Yes. Liangchuan requires proof of trademark registration in order to print or emboss your trademark onto the product or packaging.

Q. Do Liangchuan products come with a warranty ?
A. Yes. That's why we offer 3-year product life guarantee, and a generous1 year warranty on all purchases that begins with the bill of loading.

Q. How can I get some samples?

A. Usually we don’t offer free sample and express fee are required, the sample cost can be deducted from your first large order.

Q. What's the MOQ of your products?

A. Our MOQ is one (1) piece/set.

Q. Are you a manufacturer with your own factory?

A. Yes, we are the manufacturer for more than 8 years

Common Sense Of Fall Lift Safety Valve

In recent years, ultra-low temperature valves have become more and more widely used, and they are one of the indispensable important equipment in petrochemical, air separation, natural gas and other industries. The working medium is not only low in temperature, but most of them are toxic, or flammable and explosive. , And strong permeability, so it determines many special requirements for valve materials and design. It is not only required to work normally at the set temperature, but also to ensure the working performance at room temperature.

Compared with normal temperature valves, cryogenic valves have higher packing parts and use extended stems. Its purpose is to reduce the heat introduced into the device from the outside; to ensure that the temperature of the stuffing box is above 0°C, so that the packing can work normally; to prevent the valve stem and valve cover in the stuffing box from being too cold due to the part of the stuffing box The upper parts are frosted or frozen.

China PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank supplier

PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

Inquiry Cart 0