Single phase 200~240V Elevator integrated controller with elevator parts
Products features
Support high building | Max.8 floors without external card, Max.16 floors with external card. |
Economic | Complete parallel communication without additional accessories. 4 build-in high voltage input and switch can be compounded by saftware. |
Flexible display board application megod | Support display board in 7 segment, BCD code and Grey code. In addition, series communication display board is selectable. |
Electrical data | |
Input voltage | Single phase 200~240V Single/Three phase 200~240V Three phase 200~240V Three phase 380~460V wave deviation not exceed±10%, unbalanced rates<3% |
Input frequency | 50/60Hz±5% |
Output voltage | 0~Input voltage |
Output frequency | 0~100.0Hz |
Input/Output | |
Analogue input | AI:Voltage -10~+10V |
Digital input | X1~X24,X29 |
High voltage input | X25~X28 |
Relay output | Y0~Y24 Contactor capacity:250VAC/3A or 30VDC/1A |
Button terminals | L1~L24 |
Elevator basic characteristic | |
Floor | 10 floors in standard(can be extended to sixteen floors) |
Running speed | Max.1.5m/s |
Communication mode | Complete parallel communication and series communication is selectable |
Production and installation size
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.