Full Automatic Transformer Test Bench , IEC 60076 Transformer Testing Equipment

Brand Name:RISING
Certification:ISO CE
Model Number:RSBTT III
Minimum Order Quantity:1 Set
Delivery Time:20 working days
Payment Terms:T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: 1st Floor, Block B, Innovation Park, Changzui Science and Technology Park, Sixth High-tech Road, Jiangxia District, Wuhan City, Hubei Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Full Automatic Transformer Testing Equipment No-load and Load Loss Test Transformer Test Panel Test board

Product Description
A.Manual functions
■Manually save the records to the data base.
■The data communication can be done through the PC software and the loss tester in the process of testing.
■The testing project can be selected by the button, only one testing task can be operated at the same time.
■All the testing functions and process are controlled by the button in the front panel of the test bench.
B.Full automatic functions
■The PC software can control the process with mouse and keyboard during the testing.
■The testing data can be automatically recorded and saved in the data base.
■The button in the front panel can be invalid while operating automatically.
■The testing project can be selected by the button in the dialog box, only one task can be operated at the same time.
■The temperature will be recorded automatically during no-load or load testing.
■The constant power and current can be controlled automatically during the temperature-rise testing. The temperature can be recorded for every 15 seconds(or other optional interval).
■The testing results such as insulation resistance can be recorded manually to update the test report.
■The testing result will be calibrated according to the latest standard requirements such as GB1094,IEC 60076 or ANSI C57.
■The data can be saved automatically when the experiment is complete, and the test report can be printed immediately.
■The test data can be calculated automatically during the temperature-rise test.
■The waveform calibration, rated voltage calibration and frequency calibration (50HZ,60HZ) can be automatically run against the no-load testing data.
■The temperature calibration can be run against the testing data(75℃,100℃,120℃,145℃), the rated current and frequency can also be calibrated.
■High side voltage can be monitored, recorded and frequency spectrum analyzed during no-load testing.
■Low side voltage can be monitored, recorded and frequency spectrum analyzed during load testing.
Technical Parameters:
Item
Scope of Measurement
Relative Error
Voltage
0.1-800V
±(0.2% reading + 0.1% range)
Current
0.1-300A
±(0.2% reading + 0.1% range)
Power
U*I
±(0.2% reading + 0.1% range)
Power factor
0.1-0.9999
±3 figures
Power supply
AC 380V±10% 50Hz±2%
Operating condition
Working temperature: -20℃-40℃ Relative humidity <90%
Outline dimension
Customization
Weight
Customization