1-48'' Pipe Size Portable Flowmeter Clamp On Ultrasonic Flow Meter

Model Number:ML-6100S
Minimum Order Quantity:1
Delivery Time:7-10 working days
Payment Terms:T/T
Place of Origin:China
Price:Negotation
Contact Now

Add to Cart

Site Member
Location: Shanghai Shanghai China
Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
Supplier`s last login times: within 13 hours
Product Details Company Profile
Product Details

1-48'' Pipe Size Portable Flowmeter Clamp On Ultrasonic Flow Meter

I. Introduction

ML-6100S is a wall-mount, clamp- on type ultrasonic flow meter which uses the transit-time technology. Designed using FPGA chip and low-voltage broadband pulse transmission.Both clamp on type sensors and insertion type sensors are available.

ML-6100S has a 240*128 back lit LCD with 4 line menu display and also the clear,user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly yearly totalizer. Parallel operation of positive, negative and net flow totalizer with scale factor (span) and BTUcapacity. While the output of totalizer pulse and frequency output are transmitted via relay and open collector.


ML-6100S can be used in conjunction with the RTD module and the PT1000 temperature sensor to become an energy meter for measuring the heat and cold consumption of heating pipelines and air-conditioning refrigeration pipelines;The PT1000 uses high-temperature resistance lines, imported movements,and its sensitivity and working conditions durability are much higher than those of domestic PT100.


II. Specification

Performance
Velocity Range±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy±1% of measured value
Repeatability0.2% of measured value
Linearity±1%
Pipe SizeDN25~DN1200(A pair of sensors)
Function
OutputAnalog output: 4~20mA, max load 750Ω.
Pulse output: 0~10KHz
CommunicationRS232/RS485 Modbus
Power Supply10~36VDC/AC90~245V
Display240*128 back lit LCD
TemperatureTransmitter: -14℉~140℉(-20℃~60℃)
Transducer:-40℉~176℉(-40℃~80℃,TT01)
Transducer:-40℉~266℉(-40℃~130℃,TT03)
HumidityUp to 99% RH,non-condensing
Physical
TransmitterPC/ABS,IP65
TransducerEncapsulated design,IP68
Double-shielded transducer cable
Standard/maximum cable length:30ft/1000ft(9m/300m)

III. Product Size

  • Transmitter

  • Transducer

IV. Installation Site Selection

The first condition for ultrasonic flow meter is the pipe must be full of liquid, the bubbles will greatly influence the accuracy of the measurement, please avoid the follow installation position.

The suggestion installation area is as following:

A is for upright pipeline, please notice the water direction is from the bottom to top.

B is for horizontal pipeline, the transducers need to be installed inside the C area,angle for area C, max 120°


V. Photos

China 1-48'' Pipe Size Portable Flowmeter Clamp On Ultrasonic Flow Meter supplier

1-48'' Pipe Size Portable Flowmeter Clamp On Ultrasonic Flow Meter

Inquiry Cart 0