Home /Counters /

RS485 Ultrasonic Flow Meter

RS485 Ultrasonic Flow Meter

Model Number:ML-6100S
Minimum Order Quantity:1
Delivery Time:7-10 working days
Payment Terms:T/T
Place of Origin:China
Price:Negotation
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
Supplier`s last login times: within 13 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

RS485 Ultrasonic Flow Meter Sensor With High Temperature Up To 130C

I. Introduction

ML-6100S is a wall-mount, clamp- on type ultrasonic flow meter which uses the transit-time technology. Designed using FPGA chip and low-voltage broadband pulse transmission.Both clamp on type sensors and insertion type sensors are available.

ML-6100S has a 240*128 back lit LCD with 4 line menu display and also the clear,user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly yearly totalizer. Parallel operation of positive, negative and net flow totalizer with scale factor (span) and BTUcapacity. While the output of totalizer pulse and frequency output are transmitted via relay and open collector.


  • External clamping flow meter sensor, simple and convenient installation, high flexibility
  • Integrated design and manufacturing, the true meaning of IP68 waterproof
  • Hidden pipe design, more beautiful after installation

ML-6100S can be used in conjunction with the RTD module and the PT1000 temperature sensor to become an energy meter for measuring the heat and cold consumption of heating pipelines and air-conditioning refrigeration pipelines;

The PT1000 uses high-temperature resistance lines, imported movements,and its sensitivity and working conditions durability are much higher than those of domestic PT100.


II. Working Principle

The external clamping or pipe type ultrasonic flow meter is an instrument to measure the liquid flow in the circular tube on the principle of speed difference method. It adopts advanced multi-pulse technology, signal digital processing technology and error correction technology, so that the flow meter can adapt to the environment of industrial site more conveniently, economically and accurately. Products reach the advanced level at home and abroad, can be widely used in petroleum, chemical, metallurgy, electricity, water supply and drainage and other fields.


III. Specification

Performance
Velocity Range±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy±1% of measured value
Repeatability0.2% of measured value
Linearity±1%
Pipe SizeDN25~DN1200(A pair of sensors)
Function
OutputAnalog output: 4~20mA, max load 750Ω.
Pulse output: 0~10KHz
CommunicationRS232/RS485 Modbus
Power Supply10~36VDC/AC90~245V
Display240*128 back lit LCD
TemperatureTransmitter: -14℉~140℉(-20℃~60℃)
Transducer:-40℉~176℉(-40℃~80℃,TT01)
Transducer:-40℉~266℉(-40℃~130℃,TT03)
HumidityUp to 99% RH,non-condensing
Physical
TransmitterPC/ABS,IP65
TransducerEncapsulated design,IP68
Double-shielded transducer cable
Standard/maximum cable length:30ft/1000ft(9m/300m)

IV. Configuration

ModelTransmitter
ML-6100SWall-mounted Type
Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy :±1% of the measure value
Repeatability:0.2% of the measure value
Display:240*128 back lit LCD
Power Supply: 10~36VDC/AC90~245V
Transmitter Enclosure: IP65, ABS (Temperature: -20℃~50℃)
Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option
Communication: RS232,RS485
CodeOutput
1OCT,Relay,RS232/RS485,4-20mA
2OCT,Relay,RS232/RS485,4-20mA, RTD
CodeTransducer
TT01Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃)
TT03Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃)
TT05Insertion, IP68. Operating temperature:-40 ℉ ~ +266 ℉(-40℃ ~ +130 ℃)
CodeTransducer Cable Length
030Standard length 30ft (9m)
XXXMax length to 1000ft (300m)
CodeTemperature Transducer
PT1000PT1000 temperature transducer+RTD module(option)
CodeData Logger
SDSD card(8G)+ SD card module(option)

Standard model: ML-6100S-1-TT01-030

Description: Standard clamp-on type ultrasonic flow meter, OCT, Relay,

RS485, 4-20mA, 30ft cable with TT01 transducers


V. Installation Site Selection

The first condition for ultrasonic flow meter is the pipe must be full of liquid, the bubbles will greatly influence the accuracy of the measurement, please avoid the follow installation position.


The suggestion installation area is as following:

A is for upright pipeline, please notice the water direction is from the bottom to top.

B is for horizontal pipeline, the transducers need to be installed inside the C area,angle for area C, max 120°

China RS485 Ultrasonic Flow Meter supplier

RS485 Ultrasonic Flow Meter

Inquiry Cart 0