Home /Oil Field Equipment /

High Precision Vortex Gas Flow Meter DN50 Low Pressure Loss Pulse Output

High Precision Vortex Gas Flow Meter DN50 Low Pressure Loss Pulse Output

Model Number:LUGBML
Minimum Order Quantity:1pc
Delivery Time:7-10 working days
Payment Terms:T/T
Place of Origin:China
Price:Negotiation
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
Supplier`s last login times: within 13 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Vortex Flowmeter DN50 to Measure Gas with High Precision


1. Introduction

LUGBML based on the vonkarman vortex principle, piezoelectric crystals are used as test elements. It is a new type of vortex flowmeter for stress detection. It has the advantages of large measuring range ratio, high precision, small pressure loss, good versatility of medium, proportional pulse output to flow rate and convenient connection with computer, because the probe and eddy current generator of the sensor are installed separately, and the high temperature resistant piezoelectric crystal does not touch the instrument. LUGBML series of vortex flowmeter sensors can be used to detect and measure the flow rate of various gases, liquids and vapors. Can be used with our ML6000 series vortex Flowmeter. It can also work with computers and temperature, pressure, density sensors to form a high-precision mass flow or heat flow detection system.


2. Working Principle

The vortex flowmeter is a volume flowmeter which measures the volume flow of gas, steam or liquid, the volume flow or mass flow of gas, steam or liquid according to the Karman vortex street principle.

It is mainly used to measure the flow rate of medium fluid in industrial pipeline, such as gas, liquid, steam and so on.

It is characterized by small pressure loss, wide measuring range and high precision, and is almost not affected by fluid density, pressure, temperature, viscosity and other parameters when measuring volume flow under working conditions.

There are no movable mechanical parts, so the reliability is high and the maintenance quantity is small.

The instrument parameters can be stable for a long time.

The vortex Flowmeter adopts piezoelectric stress sensor with high reliability and can work in the working temperature range of-20 ℃ ~ + 250 ℃.

There are both analog standard signal and digital pulse signal output, which is easy to be used with computers and other digital systems, so it is a relatively advanced and ideal measuring instrument.


3. Specifications

1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)

2) Accuracy:Liquid:1.0% Gas:1.5%

3) Repeatability:Liquid 0.33% Gas:0.5%

4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s

5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)

6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)

7) Body material:304 stainless steel(SS316 is optional)

8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485

9) Power supply:24VDC(12VDC),Lithium battery

10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)

11) Relative humidity:5~95%

12) Protection level:IP65

13) Electrical connection:M20*1.5


4. Dimensional Sketche

DNA(mm)B(mm)C(mm)
256565368
326665374
408076382
508089388
6593102402
80100114408
100126136435
125146160463
150166182489
200196248543
250210282596
300240334648

5. Configuration

LUGBML Series Vortex Flow Meter Configuration
ModelLUGBML
Sensor InstallationDClamp Type Sensor
FFlange Type Sensor
CInsertion Type Sensor
MediumLLiquid
GGas
SSteam
Pipe Material2525mm
......
300300mm
Power SupplyADuplicate Supply(24VDC/12VDC+3.6V Lithium Battery)
B3.6V Lithium Battery
C24VDC/12VDC
DisplayDWith Digital Display
PWithout Digital Display
OutputNNone
PPulse
A4-20mA
RRS485
HHart
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers
Sensor MaterialA304 SS (Standard)
B316 SS
OOthers
Medium TemperatureE40~250℃
H100~350℃
Rated Pressure161.6MPa
252.5MPa
404.0MPa
OOthers
Protection Class0IP65
Explosion Proof0None
EXExplosive Proof

6. Design & Installation


It is important to install meter,if not installed well, then would affect precision, use-life and damage.

1. To avoid strong current, high frequency and powerful switch set, power supply of meter shall be avoided to near by these equipments.
2. To avoid high-Temp & radiation source. if have to install it, need heat insulation & ventilated measure.
3. To avoid high-Temp & enchant gas, if have to install it, need ventilated measure.
4. Vortex flow meter shall be avoided to install on shaking part of pipeline. If have to install on it,shall add clamp device and vibration pad which located on 2D to enhance shake proof . meter has better to installed indoors, pay attention to waterproof when installing meter outdoors,special notice the joint, make cable conductor to U shape to avoid water get into the amplifier body Around installing place shall save enough space,so that install connection line and maintenance routine.


7. Details


China High Precision Vortex Gas Flow Meter DN50  Low Pressure Loss Pulse Output supplier

High Precision Vortex Gas Flow Meter DN50 Low Pressure Loss Pulse Output

Inquiry Cart 0