Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0% Accuracy

Model Number:LUGBML
Minimum Order Quantity:1pc
Delivery Time:7-10 working days
Payment Terms:T/T
Place of Origin:China
Price:Negotiation
Contact Now

Add to Cart

Site Member
Location: Shanghai Shanghai China
Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
Supplier`s last login times: within 13 hours
Product Details Company Profile
Product Details

Vortex Flow Meter DN100 Made in China with RS485 Output


1. Introduction

LUGBML is based on vonkarman's vortex principle and uses piezoelectric crystals as the test element. It is a new type of stress detection vortex flowmeter. It has the advantages of large turndown ratio, high accuracy, small pressure loss, good medium versatility, pulse output proportional to flow rate, and convenient connection with computer. Because the sensor's detection probe and eddy current generator are installed separately, the high temperature resistant piezoelectric crystal is not The contacting instrument has simple structure, good versatility and high stability. LUGBML series vortex flowmeter sensors can be used to detect and measure the flow of various gases, liquids and steam. It can be used with our company's ML6000 series vortex flowmeter. It can also cooperate with a computer and temperature, pressure, and density sensors to form a high-precision mass flow or heat flow detection system.


2. Features

  • The vortex flowmeter has a simple and firm structure, no moving parts, and good stability.
  • Simple installation and convenient maintenance.
  • The measurement range is wide, the ratio is as high as 10:1.
  • Compensate the liquid volume as required, and there is no need to recalibrate the meter coefficient after replacing the accessories.

3. Specifications

1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)

2) Accuracy:Liquid:1.0% Gas:1.5%

3) Repeatability:Liquid 0.33% Gas:0.5%

4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s

5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)

6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)

7) Body material:304 stainless steel(SS316 is optional)

8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485

9) Power supply:24VDC(12VDC),Lithium battery

10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)

11) Relative humidity:5~95%

12) Protection level:IP65

13) Electrical connection:M20*1.5


4. Dimensional Sketche

DNA(mm)B(mm)C(mm)
256565368
326665374
408076382
508089388
6593102402
80100114408
100126136435
125146160463
150166182489
200196248543
250210282596
300240334648

5. Design & Installation


The installation of the instrument is very important, if the installation is not good, it will affect the accuracy, service life and damage.


1. In order to avoid high-power, high-frequency, high-power switch groups, instrument power supplies should be avoided near these devices.


2. Avoid high temperatures and radiation sources. If installation is required, thermal insulation and ventilation measures should be taken.


3. In order to avoid high temperature and enchanted gas, ventilation measures should be taken if installation is needed.


4. The eddy current flowmeter should not be installed in the sloshing part of the pipe. If it must be installed on it, a clamping device and a vibration pad located in 2D should be added to enhance shock resistance. It is best to install the instrument indoors, pay attention to waterproof during outdoor installation, and pay special attention to the joint to make the cable wire U-shaped, so as to prevent water from entering the amplifier body, and enough space should be saved at the installation place for installation and routine maintenance.


6. Packing

China Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy supplier

Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0% Accuracy

Inquiry Cart 0