Military Product Fuel Saving 200KW 250KVA Huachai Deutz Open heavy duty diesel generator


DEUTZ is one of the world’s leading manufacturers of innovative drive systems. Its core competences are

the development, production, distribution and servicing of diesel, gas and electric drivetrains for

professional applications. The engine specialist offers a broad product spectrum with capacities ranging

up to 620 kW that is used in construction equipment, agricultural machinery, material handling equipment,

stationary equipment, commercial vehicles, rail vehicles and other applications.




PRODUCT DESCRIPTION
Genset ModelBS-D250
Prime Power (kw/kva)200 / 250Standby Power(kw/kva)220 / 275
Voltage (v)400Rated Speed (rpm)1500
Frequency (Hz)50Rated Current (A)360.8
Connection:3 phasePower Factor:0.8
Engine Model:BF6M1015-LA G1AAlternator Model:UCDI274K
Net Weight (kgs)-Silent2800Dimensions (mm)-Silent3450x1100x2070
Engine Parameter:

Manufacturer/Model

Engine type


Control System

Displacement

Bore x Stroke

Compression Ratio

Power

Effective pressure

MAX. exhaust gas temperature

Inlet air (25 /1000mbar)

Fuel Consumption

Max. noise value at 1m

Battery voltage(V)

Starter rated power (KW)

Generator voltage(V)

Max. exhaust back pressure (mbar)

Max. allowable air inlet resistance (mbar)

Lowest ambient temperature of

cold starting without assistant

Lowest ambient temperature of cold

starting with flame preheat plug

DEUTZ BF6M1015-LA G1A
4-Cycle,6-Cylinder,V-form,Turbocharged,

CAC Inter-cooling

mechanical /electronic

11.906 L

132 x 145 mm

16.5 : 1

250 KW

16.8 bar

463℃

1124 m3/h

196g/kw·h

≤94 dBA

24

9

28.5

50

50


-17℃


-32℃

Fuel System

Cylinder ignition sequence

Idle speed (rpm)

Low-pressure pump oil load capacity (L/h)

Fuel filter element type

No. of the fuel filter element

1-6-3-5-2-4

600±50

190

Disposable filter

2

Lube System

Oil Consumption (as % of fuel consumption)

oil temperature 90℃

Min. oil pressure at 1500rpm

Min. oil pressure at 600rpm

Oil temperature of normal operation

Initial oil filling

Oil filter element type

No. of oil filter element

<0.3% of fuel consumption


≥3 bar

≥1 bar

<130 ℃

38 L

Disposable filter

1

Cooling system

Engine coolant capacity( L)

Water-pump flow (L/min)

Water-pump pressure (bar)

Allowable pressure loss of cooling system (include pipeline) (bar)

Heat carry off by coolant (kW)

In&Outlet coolant size (mm)

Temperature of switch on two thermostats respectively (℃)

Temperature of switch on two thermostats totally (℃)

Max. allowable operating temperature (℃)

Temperature difference between inlet and outlet coolant (℃)

Inter-cooler cooling power(KW)

Fan

Fan connection

Fan diameter (mm)

Air volume of fan(m3/s)

Fan power consumption (kW)

Fan transmission ratio

17

260

1.25


≤0.35

138

70


79/87


94/102

103


≤8

52

Exhaust type

Gear drive + coupler

880

4.6

≤14

0.96

Alternator Parameter: Basic Information

The alternators meet the standards of:

GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350

Technical Data

Manufacturer

Phases

Bearing numbers

Power Factor

Protection Class

Altitude Condition

Excitation

Insulation class/Temp. rise class

Tel. Influence Factor TIF

Tel. Harmonic Factor THF

Steady State Voltage Regulation

Alternator Capacity

Efficiency

STAMFORD UCDI274K

3

1

0.8

IP23

≤1000M

Brushless, self-excitation

H / H

<50

<2%

≤±1%

200KW

92.7%


Standard configuration of diesel generator set for open type :


1 . all kinds of engine brand as options for customer

2 . Stamford alternator ( Copy stamford or other brand for option )

3 . SMARTGENT or Deepsea control panel

4 . circuit breaker

5 . 8 Working Hours Base Fuel Tank , many kinds of base frame for options .

6 . Anti-Vibration Mounted System

7 .Battery and battery charger

8 . Industrial silencer and flexible exhaust hose


FAQ

Q : What is the difference between Prime power and Standby power ?
A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited

Q : How to choose the power ?
A : Collect all power of your equipments , take the current into your consideration .

Q : Does your generator have global warranty?

A : Yes . Global warranty service is available depending on the engines and alternators you choose .

Q:What is your MOQ?
A: Above 1pc

Q: Do you offer OEM service?
A: Yes

Q: What is your lead time?
A: About 30 days after receiving deposit or original L/C.But if your order with some special design,

then the delivery time is longer.

Q: What is your payment term?
A: 30% T/T in advance, the rest payment before shipment. Or irrevocable L/C.