630A Mechanism Vacuum Circuit Breaker For Arc Interruption

Brand Name:XK
Certification:ISO9001 / GB / IEC
Model Number:ZN63-12/630A
Minimum Order Quantity:>=1 Pieces
Place of Origin:Zhejiang, China
Price:Negotiation
Contact Now

Add to Cart

Active Member
Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Hot sale 12KV 50HZ permanent magnetic mechanism three-phase vacuum circuit breaker

ItemUnitData
Rated voltageKV12
Rated frequencyHZ50
Rated insulation level1min Power frequency withstand voltageKV42(fracture 48)
Peak Lightning lmpulse Withstand voltageKV75(fracture 84)
Rated Breaking CurrentKA202531.540
Rated CurrentA6306301250 16001250 1600
125012502000 25002000 2500
Rated short time withstand currentKA
20
25
31.5
40
Rated peak withstand currentKA
50
63
80
100
Rated short circuit breaking currentKA
50
63
80
100
Rated continous time under short circuit currentS4
Secondary power frequncy withstand voltageV2000V

Product Description


Vacuum Arc Stability:

In a 50 Hz ac circuit the current passes through zero value 100 times in a second (i.e., once every 10 ms). It is desirable that the current is interrupted when it is passing through zero value, otherwise overvoltage will be induced due to current chopping. Therefore, for successful arc interruption it is necessary that the arc be stable for half-cycle duration and particularly that it continues to exist at currents approaching zero.

The arc stability is found to depend upon:

(i) The contact material and its vapour pressure and

(ii) Circuit parameters such as voltage, current, capacitance and inductance.

In low current circuits most of the evaporation takes place at discrete points, called the cathode spots, while at higher currents the evaporation takes place from cathode and anode spots. In addition to these sources gas is added to the enclosure of the contacts when it is stripped from other parts of the enclosure because of high temperature and impinging metal vapour.

Vapour pressure and arc stability are found to be interrelated. The higher the vapour pressure at lower temperature, the better is the stability of the arc i.e., the longer the life time of the arc. There are certain metals like Zn, Bi, which provide such characteristics and are better electrode materials for vacuum circuit breakers. Besides the vapour pressure, the thermal conductivity of the metal also affects the current chopping level.

A good heat conducting metal will cool very rapidly and its contact surface temperature will fall. This will reduce the evaporation rate and the arc will be chopped because of insufficient vapour. On the other hand, a bad heat conductor will maintain its temperature and vaporization for a longer time and the arc will be more stable.


Shunting the contacts with different values of capacitance reduces the average life time of the arc. The higher the value of the capacitance, the lower is the average life time of the arc. An inductance in series, on the other hand increases the lifetime of the arc. Similarly, higher the system operating voltage, longer is the duration of the arc. This is because more restoring voltage is available to keep the arc alive.