11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

Brand Name:XK
Certification:ISO9001 / GB / IEC
Model Number:FN12
Minimum Order Quantity:1 Piece/Pieces
Place of Origin:china
Supply Ability:100 Piece/Pieces per Month
Contact Now

Add to Cart

Verified Supplier
Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

11kv load break switch 3 phase load break switch indoor load break switch

Hot sale 11KV safety indoor AC high voltage load breaker switch

Product Description

ltemUnitData
Rated voltageKVFN12-12D/630FN12-12(R)D/125
Rated frequencyHZ12
Rated currentA50
1min power frequency withstand voltageKV42 to ground and phases fracture 48
Lightning impulse withstand voltageKV75 to ground and phases fracture 85
Rated thermal stable currentKA
630
100
Rated dynamic stable currentKA
50
Rated switching current(peak)KA
50
50
Rated short-circuit current(expected)KV
31.5
Maximum breaking current thresholdHZFuse characteratic curve accorting
Minimum breaking currentAFuse characteratic curve accorting
Rated transfer currentKV
50
1.5
Maximum breaking currentKV1.8
Breaking OFF-load transformer capacityKV/A1250
Rated cable charging currentA10
Rated active load current breaking timesTimes10000
Opening time when striker strikesS<0.06
Earth switch thermal current switchKA20(2S)
Thermal stable current of earth switchKA5050
Motor operating power supply voltageVAC/DC 110/220

11kv load break switch 3 phase load break switch indoor load break switch

ltemUnitData
FN12-10D/630FN12-10(R)D/125
The total traveling distance of moving contactmm200+8-2
Phase center distance (Before energy storage)mm210±15
Moving contact overtravel distancemm40±2
Auxiliary contact opening distancemm>150
Opening/Closing time difference among three phasems<3
Opening speedm/s>2.8>2.8
Closing speedm/s>3.8
Distance between metal flexible door and torchmm>125
Fracture distance of earth switchmm>150
Main circuit resistanceΩ<120<300
Maximum operating torqueNM>160

11kv load break switch 3 phase load break switch indoor load break switch


Ascending changes in the way we generate, transmit and use of electricity in developed economy or highly industrialised society, prioritised the maintenance of continuity of supply to consumers. With the goal to be integrated in smart cities, the safety of electrical equipment by fast disconnection of the power supply in case of fault events like leakage current, electrical arc, over current or overvoltage is taken care through switchgear such as disconnecting switches, circuit breakers, etc. For the systems up to 33kV, the more costly circuit breakers are getting replaced with load break switches. A load break switch is a type of switching device used for voltages in the range of 12 to 36 kV and must have the following capabilities:

- Interruption of current equal to its continuous current rating at the system voltage and the power factor of the normal load
- Designed to possess enough insulation to isolate the circuit in closed position.
- Interrupting small capacitive and inductive currents which is essential for disconnecting the unloaded overhead lines, transformers, cables, etc.
- Carrying the maximum fault current for the duration required by the interrupting device to clear the fault.
- Making on the terminal fault at rated voltage.

The basic functional difference between Load break switch and circuit breaker is that the former cannot interrupt the short circuit currents. The following figure 1 shows the how the load break switches are employed in a substation.

China 11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency supplier

11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency